Air conditioner cycles on and off too much.

Water drips from cabinet into your house.

Check if

The air conditioner is not
properly sized for your
room.

Then

Check the cooling capabilities of your room conditioner. Room
air conditioners are not designed to cool multiple rooms.

The filter is dirty or ob
structed by debris.

The inslde evaporator and
outside condenset coils
are dirty or obstructed by
debris.

There is excessive heat or
moisture from cooking,
showers, etc.in the room

The louvers are blocked.

The outside temperature is
below 65

0

F (18

0

C).

The temperature of the
room you are trying to cool
is extremely hot.

Windows or doors to the
outside are open.

The EXHAUST is set to
OPEN.

The THERMOSTAT Con-
trol is not at a cool enough
setting.

Clean the filter See page 5.

Clean the inside evaporator and outside condenser coils.
See page 6.

Use a fan to exhaust heat or moisture from the room. Try not
to use heat-producing appliances during the hottest part of
the day.

Install the air conditioner in a location where the louvers are
free from curtains, blinds, furniture, etc.

Do not try to operate your air conditioner in the cooling mode
when the outside temperature is below 65

0

F(18

0

C).

Allow extra time for the air conditioner to cool off a very hot
room.

Close all windows and doors.

Set the EXHAUST Control to CLOSED for maximum cooling.

Adjust the THERMOSTAT Control to a cooler setting by tuming
the knod clockwise, Tum UNIT CONTROL to HIGH COOL.

The air conditioner is in-
stalled on the sunny side of
your house.

Install your air conditioner in a more shaded window.

Check if

Then

The air conditioner is prop-
erly leveled. The air condi-
tioner should slope slightly
downward toward the
outside.

Level the air conditioner to provide a downward slope toward
the outside (1/2 bubble on a carpenter’s level) to ensure proper
drainage. See the lnstallation lnstructions.
Reposition or shim the cabinet as necessary.

NOTE:Do NOT drill a hole in the bottom of the metal base
and condensate pan.