SPECIFICATION

Model no.

WA-1300E
WA-1310E

WA-1300H
WA-1310H

Cooling capacity

13000 BTU/hr

13000 BTU/hr

Heating capacity

-

13000 BTU/hr

Power/Ampere
consumption for cooling*

1071

W/ 9.4

A

1071

W/ 9.4A

Power/Ampere
consumption for heating*

-

1071W/ 9.4A

Air volume (max. speed)

580m

3

/h 580m

3

/h

Humidity removal capacity

98 Pts

/day

98 Pts

/day

Recommended room size

420sq.ft.

420sq.ft.

Power supply

115V/60Hz/1phase

Compressor Rotary
Refrigerant

R-22

Refrigerant load*

15.2 oz

Fan speed

3

Timer

1~ 24 hours

Working temperature

Cooling: 64.4

o

F~ 110

o

F

Heating: 41

o

F~ 80.6

o

F

Thermostat

62

o

F ~ 90

o

F

Exhaust pipe

5 in x 59 in

Net Weight

86 lbs.

Dimension

14 x 21 x 30 in (WxDxH)

REMARK:

1. The data marked with '*' may vary for technical reasons.
2. Measuring condition for above is: Cooling – RT80.6

o

F, RH60%

Heating – RT68

o

F, RH60%

*RT means room temperature
*RH means room humidity.

Un-insulated rooms such as sunrooms, garages, or attics should be less
than 420sq.ft.

The following may effect the unit in reaching your set tempearature:
Outside Temperature, Room Size, Ceiling Height, Room Insulation,
Number of people in the room, Direct Sunlight and Source of Heat.