PROBLEM

POSSIBLE CAUSE

SOLUTION/REASONS

Ammeter reads less than

selected charge rate when

charging a discharged

battery.

Extension cord too long or

wire gauge too small.
Weak cell or sulfated plate

in battery.

Battery is only partially

discharged.

Use shorter or heavier

gauge extension cord.
Sulfated battery will

eventually take a normal

charge if left connected. If

the battery will not take a

charge, have it tested by a

Sears technician.
Continue charging battery.

Charger makes a loud

buzz or hum.

Transformer laminations

vibrate (buzz).
Shorted diode (hum).

Continue charging. Buzz

is not abnormal.
Have charger tested by

Sears technician.

Ammeter reading stays

high.

Battery is severely dis-

charged.

Continue charging battery

for two more hours. If

problem continues, have

the battery checked by a

Sears or other qualified

service dealer.