Case 1. Starting failure

CHECK

PROBABLE CAUSES

ACTION

Fuel tank

Incorrect fuel

Drain it and fill with correct fuel

Fuel filter

Fuel filter is clogged

Clean

Carburetor idle speed screw

Out of normal range

Adjust to normal range

No spark

Spark plug is fouled/wet

Clean/dry

Plug gap is incorrect

[Correct GAP .025" (0.6~0.7 mm)]

Spark plug

Disconnected

Retighten

Case 2. Engine starts but does not keep running/Hard re-starting

CHECK

PROBABLE CAUSES

ACTION

Fuel tank

Incorrect fuel or stale fuel

Drain it and fill with correct fuel

Carburetor idle speed screw

Out of normal range

Adjust to normal range

Muffler, cylinder(exhaust port)

Carbon is built-up

Wipe away

Air cleaner

Clogged with dust

Wash

Cylinder fin, fan cover

Clogged with dust

Clean