Server Technology CDUCW-16V-MX User Manual

Sentry switched cdu, Cw-16v (20-amp), Key features

Advertising
background image

Model

Available Input

Voltages

Outlets

Available Input

Cord

Amperage

Dimensions

(L x W x D)

© Server Technology, Inc. 01/26/2007 version. Information in this document is subject to change without notice. Sentry is a trademark of Server Technology, Inc.
Protected by one or more of the following patents: Patent # 7,043,543. Patent Pending. Printed in US.

Sentry : Solutions for the Data Center Equipment Cabinet

Key Features

Sentry : CDU Technical Specifications

Sentry Switched CDU

CW-16V (20-Amp)

High-Density Power Distribution

The Switched CDU’s combine remote configuration and management
with power distribution and power and environmental monitoring.
Reboot a single or dual-power server with one command. Receive
SNMP-based alerts and email alerts when power or environmental
conditions exceed thresholds. Assign users specific access rights to
designated outlets or groups.

Only the Switched CDU products provide the flexibility needed for all
data centers and remote sites, including power requirements for
high-amp, high voltage; UL 60950-1 (branch circuit protection not
required for 20A rated devices); SSL & SSH security; and SNMP-based
input current monitoring.

The Switched CDU also supports Enterprise View PDU Manager.
This gives the engineer the ability to manage a large installation of
Networked CDUs from one location, view and access up to 1,000
Switched CDUs from a

single web interface.

> Remote Power Management:

Power cycle individual power

outlets, or groups of power

outlets, to remotely reboot

servers and network devices,

anywhere in the world. Or,

power-off unused power

receptacles

> High Power Distribution: 120V,

208V, or 230V power; 20-Amp

power input feed option

> High Density: Single power

input feed; 16 outlets per

enclosure

> IP Access & Security: Web

interface, SSL, SSH, Telnet, SNMP,
FTP, SNTP, Syslog, LDAP, LDAPS,
TACACS

and RS-232 access

> Add an Expansion Module:

Daisy chain the Switched CDU

Expansion Module (CW/CX) for

power management of separate

power circuits from a single IP

address

> Environmental Monitoring:

Each Switched CDU supports two

temperature & humidity probes

and reports conditions thru the

Web interface

> Enterprise View: View and

access up to 1,000 Switched

CDUs from one Web interface**

> SNMP Traps: Provide automated

alerts for power and

environmental conditions

> Input Current Monitor:

Precisely measure the aggregate

current draw (in amps) on each

power circuit. On-site

verification of the input current

with the LED digital display.

Remote verification via browser

or serial screen.

> Power-up Sequencing: Prevent

an in-rush power overload

Input Current Monitoring

The CDU’s exclusive True RMS current monitoring is critical
to preventing overloads in high-density computing
environments. LED digital displays on the CDU enclosure
report the input current of each phase or branch circuit.

Temperature and Humidity

The Switched CDU supports two external probes. Each of
these probes measure both temperature and humidity.
Receive SNMP-based alert notifications when conditions
exceed defined thresholds.

Additional Benefits:

CW-16V1-C20MX

CW-16V2-C20MX

100-120V

50/60Hz

208-240V

50/60Hz

20A

20A

IEC 60320/C20

Power Inlet

IEC 60320/C20

Power Inlet

(16) NEMA 5-20R

(16) IEC 60320/C13

39.5” x 1.75” x 2.25”

39.5” x 1.75” x 2.25”

Additional Features and Specifications

Agency Approvals

> US & Canada (cTUVus mark) to UL 60950-1:2003 and

CAN/CSA 22.2 No. 60950-1-03

> European Union (TUVGS mark) to EN 60950-1:2001

> FCC Class A, Part 15

> CE

> EMC - EN 55022 Class A, EN 55024

Communications and Security

> 10/100 BaseT Ethernet

> HTTP/HTTPS

> SSLv3/TLSv1

> SNMPv2

> SSHv2

> Telnet

> LDAPv3 and LDAPS

> TACACS+

> RS-232 (Serial)

Accessories

> Optional Temperature & Humidity Probe

EMTH-1-1 Temperature & Humidity Probe, 10’

Power Cord Options

> PTCORD-1 IEC 60320/C19 - NEMA L6-20P , 10’

> PTCORD-2 IEC 60320/C19 - Schuko 10’

> PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17)

16/20A Blue (UK Commando) 10’

> PTCORD-4 IEC 60320/C19 - BS1363 13A (UK) 10’

> PTCORD-5 IEC 60320/C19 - 5-15P (15A Straight-Blade) 10’

> PTCORD-6 IEC 60320/C19 - 5-20P (20A Straight-Blade) 10’

> PTCORD-7 IEC 60320/C19 - L5-20P (20A Twist-Lock) 10’

> PT-ADP-C19 Cable mount IEC 60320/C19 Connector

**Enterprise View sold separtely

Expansion Module
Model Numbers
> CX-16V1-C20MX
> CX-16V2-C20MX
> CX-16VE-C20MX

CW-16VE-C20MX

230V

50/60Hz

16A

IEC 60320/C20

Power Inlet

(16) IEC 60320/C13

39.5” x 1.75” x 2.25”

NORTH AMERICA / ASIA

Server Technology, Inc.

1040 Sandhill Drive

Reno, NV 89521

United States

1.775.284.2000 Tel

1.775.284.2065 Fax

[email protected]

www.servertech.com

www.servertechblog.com

EMEA

Server Technology Intl

Sienna Court

The Broadway

Maidenhead

Berkshire

SL6 1NJ

United Kingdom

+44 (0) 1628 509053 Tel

+44 (0) 1628 509100 Fax

[email protected]

Branch Circuit Protection

(not required)

> Compliant to UL 60950-1

Advertising