Sony XCD-MV6 User Manual

Page 18

Advertising
background image

Cont

ro

l

18

For offset address 434h, the length of the UnitDependentInfo is 0Bh Quadlets.

CommandRegsBase is the base address of the camera control register.

F0000000h + 3c0000h × 4 = F0F00000h

The offset address of VendorNameLeaf is required to be

43Ch + 00000Ah × 4 = 464h

The offset address of ModelNameLeaf is required to be

440h + 00000Dh × 4 = 474h

Unit_sub_sw_version conforms to IIDC Standards, Version 1.32.

Vendor_unique_info 0 to Vendor_unique_info 3 are terms of information that the vendor of the camera can define.
The meanings in this camera are as follows:

Vendor_unique_info_0 is the firmware version.
Vendor_unique_info_1 is the hardware version.
Vendor_unique_info_2 is the link version.
Vendor_unique_info_3 is the serial number of the camera.

VendorNameLeaf

For offset address 464h, the length of the VendorNameLeaf is 3 Quadlets.
The subsequent 8 bytes are fixed at 00.
After that, the four characters for “SONY” are entered.

ModelNameLeaf

For offset address 474h, the length of the ModelNameLeaf is 4 Quadlets.
The subsequent 8 bytes are fixed at 00.
After that, the model name is entered.

Offset

0-7

8-15

16-23

24-31

Vender Name Leaf

464h

0003

CRC

468h

00

00

00

00

46h

00

00

00

00

470ch

53

4F

4E

59

SONY

Offset

0-7

8-15

16-23

24-31

Model Name Leaf

474h

0004

CRC

478h

00

00

00

00

47ch

00

00

00

00

480h

58

43

44

2D

XCD-

484h

4D

56

36

00

MV6

Advertising