Applications

13

24/96 AD-DA Converter 2053

Monitoring in 24Bit/96kHz

A high standard of monitoring is necessary for
judging the recording quality. Therefore all digital
signals have to be converted into analog signals to
allow reproduction on loudspeakers or headphones.

The A/D converter stage is equipped with high-

quality components and ensures excellent tonal
results. We recommend to use the SPL converter
rather than the converters found in DAT recorders,
sound cards or digital consoles.

Analog processing of a digital signal

Together with the converter module, the inputs of the
CHANNEL ONE can also be used for digital signals to
have access to the entire processing bandwidth inclu-
ding the tube pre-amplifier.

Please consider the following instructions: the sockets
INSTR. IN (front) and LINE (back) need not be occu-
pied. The MIC/LINE switch has to be set to LINE. The
converter signal is now routed to the preamplifying
stage of the CHANNEL ONE.

The LINE socket is a switch socket - a signal connected
to the LINE socket takes priority, otherwise the
converter signal will be connected through.