OPERATION

PRE-START CHECKLIST:

1. Check oil level. Add if necessary.

WARNING: Risk of bodily injury. NEVER attempt to open the drain valve when

more than 10 PSI of air pressure is in the air tank!

3. Make sure the air compressor Motor Switch is in the “OFF” position.

4. Make sure all safety valves are working correctly.

5. Make sure all guards and covers are in place and securely mounted.

6. Make sure that air filter is placed in proper opening. Remove plug before threading housing into compressor.
START-UP:

1. Ensure the lever on the pressure switch box is in the “OFF” position.

2. Plug the power cord into a grounded outlet.

3. Move the lever on the pressure switch box to the “ON” position.

5. Set pressure by adjusting the pressure regulator knob counterclockwise for less pressure and clockwise for

more pressure.

6. If you notice any unusual noise or vibration, stop the air compressor and refer to “Troubleshooting”.

SHUTDOWN:

1. To stop the air compressor, move the lever on the pressure switch box to the “OFF” position. NEVER stop the

air compressor by unplugging it from the power source. This could result in risk of electrocution.

2. Drain air from the air tanks by releasing air with an attached air tool or by pulling on the safety relief valve rings.

3. Once pressure in the air tanks register under 10 psig, open the drain valve under each air tank to drain any

moisture.

4. Allow the air compressor to cool down.

5. Wipe air compressor clean and store in a safe, non-freezing area.

MAINTENANCE

Read the instruction manual before performing maintenance. The following procedures must be performed when

stopping the air compressor for maintenance or service.

1. Turn off air compressor.

WARNING: Never assume the air compressor is safe to work on just because

it is not operating. It could restart anytime!

2. Disconnect cord from main power supply.

3. Open all drains.

4. Wait for the air compressor to cool before starting service.

MAINTENANCE CHART

PROCEDURE

DAILY

WEEKLY

MONTHLY

200 HOURS

X

l

e

v

e

l

li

o

p

m

u

p

k

c

e

h

C

X

n

o

it

c

e

p

s

n

i

k

a

e

l

li

O

Drain condensation in air tank(s)

X

Check for unusual noise/vibration

X

X

s

k

a

e

l

ri

a

r

o

f

k

c

e

h

C

X

r

e

tl

if

r

i

a

t

c

e

p

s

n

I

X

r

o

s

s

e

r

p

m

o

c

f

o

r

o

ir

e

t

x

e

n

a

e

l

C

X

e

v

l

a

v

f

e

il

e

r

y

t

e

f

a

s

k

c

e

h

C

Change pump oil*

X

Replace air filter

X

*The pump oil must be changed after the first 50 hours of operation and every 200 hours or 3 months, whichever

comes first. Recommended non-detergent straight weights.

4.

START/STOP: Turn to the ON position. This will allow the air compressor to “START” building up pressure in

the air tanks and “STOP” when correct pressure is achieved. When pressure drops with usage, the air

compressor willautomatically “START” building up pressure again.

2. Remove any moisture in the air compressor air tank. Remove excessive pressure with an air tool or by

pulling the safety relief valve ring, then open the air tank drain valve in the bottom of the air tank. Close tightly

when drained.