Warning – Shindaiwa EB212 User Manual

Page 12

Advertising
background image

12

Eng

lish

A

b

E

s

tartInG

Warm

enGIne

The starting procedure is the same as Cold Start except DO NOT close
the choke.

Stop Switch

Move stop switch button (A) away from the STOP position.

Throttle Position

Move throttle position lever (B) midway between idle and full throttle
positions.

Recoil Starter

Place the unit on a flat clear area. Firmly grasp throttle grip with left

hand and rapidly pull recoil starter handle/rope (E) until engine fires.

IMPORTANT
Recoil starter: Use short pulls - only 1/2-2/3 of rope for starting.

Do not allow the rope to snap back in. Always hold the unit firmly.

NOTE
If engine does not start after 5 pulls, use Cold Start Procedure.

1.

2.

3.

s

toppInG

enGIne

Throttle Trigger/Throttle Position Lever

Release throttle trigger (F). Move throttle position lever (B) forward to
idle position and allow engine to return to idle before shutting engine off.

Stop Switch

Move stop switch (B) to "Stop" position.

WARNING

If engine does not stop when stop switch is moved to STOP position,
close choke - COLD START position - to stall engine. Have your
Shindaiwa dealer repair stop switch before using blower again.

1.

2.

A

F

b

Advertising
This manual is related to the following products: