2. Processes and functions

2-9

Auto. Mode for Automatic Heating/Cooling Switching

When the AUTO mode is selected, the microprocessor calculates the difference
between the set temperature and the room temperature, and automatically switches
to the COOLING or HEATING mode to maintain the desired temperature.

Room temp.

]

Set temp.

COOLING

Room temp.

<

Set temp.

HEATING

This means that if the room temperature is higher or equal to the set temperature,
COOLING operation starts. If the room temperature is lower than the set
temperature, HEATING operation starts.

Fig. 12

COOLING SELECTION TEMP.

+5 deg

SHIFT SET TEMP.

+4 deg

REMOTE CONTROLLED

SET TEMP.

SHIFT SET TEMP.

–4 deg

HEATING SELECTION TEMP.

–6 deg

HEATING

COOLING

HEATING