1. INTRODUCTION

The Syrex IS-XN is an ATEX certified intrinsically safe

beacon which will produce a visual warning in a hazardous

area. Red, Amber, Green and Blue output models are

available.

2. DESCRIPTION

The device will start to flash when power is applied to

terminals + and -. The beacon has two flash rates one double

flash per second and two double flashes per second. The

flash rate is selected by setting an internal pin header. The

unit is factory set to produce two double flashes per second.

3. SUPPLY VOLTAGE

The Syrex IS-XN beacon has been designed to operate in a

hazardous area via a 28V 300 ohm ATEX certified Zener

barrier or galvanic isolator. The beacon may be tested or

used in safe areas without a Zener barrier or galvanic

isolator, but at supply voltages above 16V the internal current

limit will function and the brightness may be reduced. The

beacon should not be continuously operated without a barrier

or isolator with a supply voltage greater than 16V.

4. INTRINSIC SAFETY CERTIFICATION

4.1 ATEX certificate

The Syrex IS-XN beacon complies with the following

standards:-

EN50014 : 1997 + A1 and A2

EN50020 : 2002

EN50284 : 1999

The EC-Type Examination Certificate SIRA 05ATEX2269X

has been issued by the Notified Body Sira. This confirms

compliance with the European ATEX Directive 94/9/EC for

Group II, Category 1G equipment. The beacon carries the

Community Mark and subject to local codes of practice, may

be installed in any of the EEA member countries.

This instruction sheet describes installations which conform

to BS EN 60079:Part14:2003 Electrical Installation in

Hazardous Areas. When designing systems for installation

outside the UK, the local Code of Practice should be

consulted.

1) The certification marking is as follows:

WARNING:

TO AVOID A POSSIBLE ELECTROSTATIC

CHARGE ONLY CLEAN WITH A DAMP CLOTH

Syrex IS-XN Beacon

II 1G EEx ia IIC T4 (-40ºC <=Ta<= +60°C)

Ui = 28V Pi = 1.2W

Ci = 0 Li = 0

0518

SIRA 05ATEX2269X

Year / Serial No. 05 / 6MB000001

Klaxon Signals Ltd.

Oldham OL4 1HW. UK.

www.klaxonsignals.com

2) The equipment may be used in zones 0, 1 and 2

with flammable gases and vapours with apparatus

groups IIA, IIB & IIC and with temperature classes

T1, T2, T3 and T4.

3) The equipment is only certified for use in ambient

temperatures in the range -40

o

C to +60

o

C and

should not be used outside this range.

4) The certificate number has an ‘X’ suffix, which

indicates that the certificate contains one of more

special conditions for safe use. Those installing or

inspecting the equipment should refer to this section

of the certificate.

5) The equipment has not been assessed as a safety-

related device (as referred to by Directive 94/9/EC

Annex II, clause 1.5).

6) Installation of this equipment shall be carried out by

suitably-trained personnel in accordance with the

applicable code of practice.

7) Repair of this equipment shall only be carried out by

the manufacturer or in accordance with the

applicable code of practice.

8) The certification of this equipment relies on the

following materials used in its construction:

Enclosure:

ABS Plastic

Lens:

Polycarbonate

If the equipment is likely to come into contact with

aggressive substances, then it is the responsibility of

the user to take suitable precautions that prevent it

from being adversely affected, thus ensuring that the

type of protection is not compromised.

“Aggressive substances” - e.g. acidic liquids or

gases that may attack metals, or solvents that may

affect polymeric materials.

“Suitable precautions” - e.g. regular checks as part

of routine inspections or establishing from the

material’s data sheet that it is resistant to specific

chemicals.

The Syrex IS-XN beacon is CE marked for

compliance with the European Explosive

Atmospheres Directive 94/9/EC and the

European EMC Directive 89/336/EEC

II 1G EEx ia IIC T4 (-40ºC <= Ta <= +60ºC)