Architectural and engineering specifications, Technical specifications, Ordering information – Kidde 976 User Manual

Page 2: Distributed by

Advertising
background image

Architectural and Engineering

Specifications

The smoke alarm shall be Kidde Model 0976 or approved equal. It
shall be powered by a 9V battery source. The unit shall incorporate an
ionization sensor with nominal sensitivity of 0.92%/ft. The temperature
operating range shall be between 40°F and100°F (4°C and 38°C) and
the humidity operating range shall be 5% - 95% relative humidity.
The alarm shall provide optional tamper resistance that locks the bat-
tery door closed. No additional pieces shall be required to activate this
feature.

The alarm shall include an easy access battery compartment that

is opened and closed by pressing on the battery door. The 9V battery
carrier will ensure proper battery power protection by not allowing the
battery door to close if the battery is placed in the unit incorrectly or if
a battery is not present. The unit shall also provide an optional tamper
resistant switch that will help prevent the battery door from being
opened.

The unit shall include a piezoelectric horn that is rated at 85 deci-

bels at 10 feet. The unit shall include the Hush® feature that silences
the unit for approximately 7 minutes if a nuisance condition occurs.
The alarm will chirp every 30 - 40 seconds while in hush mode and will
automatically reset.

The unit shall incorporate a red LED, which will flash once every

30-40 seconds to indicate the alarm is operating properly and will flash
once per every 1.5 seconds when the unit is alarming and will remain
so until the air is cleared.

The unit shall at a minimum meet the requirements of UL217,

NFPA72, and The California State Fire Marshall, NFPA101 (0ne and two
family dwellings), Federal Housing Authority (FHA), Housing and Urban
Development (HUD).

Battery Operated Smoke Alarm

w/ Front Load Battery Door

Model 0976

Technical Specifications

Model Number:

0976

Power Source:

9V Battery

Audio Alarm:

85dB at 10ft

Temperature Range: 40˚F to 100˚F (4˚C to38˚C)
Humidity Range:

5%-95% relative humidity (RH)

Sensor:

Ionization

Size:

5” in diameter x 1.79” depth

Weight:

.5lbs

LED:

Red, alarm condition

Warranty:

10 year limited warranty

Ordering Information

Single Clam UPC: 0-47871-05672-9

Twin Clam UPC: 0-47871-05678-1

**Not for sale by individual unit

**Not for sale by individual unit

Part

Dimensions

Case/

Layers/

Skid

Number

I 2 of 5

Pack Quantity

(w x d x h inches)

Weight

Skid

Skid

Weight

N/A**

N/A

Individual

14.5 x 2 x 11.25

1lbs

N/A

N/A

N/A

0976-9995

100 47871 05678 8

Cut Case (10 units)

16 x 20.75 11.75

10lbs

16

4

160lbs

21005691

200 47871 05678 5

Power Tower (30 units)

20 x 24x 41 (incl. Pallet)

30lbs

3

3

30lbs

1

UNIT

CUT CASE

10

UNIT

CUT CASE

PDQ

1

2

12

POWER TOWER

30

1

UNIT

CUT CASE

10

UNIT

CUT CASE

PDQ

1

2

12

POWER TOWER

30

Part

Dimensions

Case/

Layers/

Skid

Number

I 2 of 5

Pack Quantity

(w x d x h inches)

Weight

Skid

Skid

Weight

N/A**

N/A

Individual

7 x 3 x 11

.5lbs

N/A

N/A

N/A

0976-9997

100 47871 05672 6

PDQ (2 units)

7.75 x 6 x 11.75

1lb

105

7

105lbs

0976-9996

200 47871 05672 3

Cut Case (12 units)

16 x 20.75 x 11.75

6lbs

18

3

108lbs

21006133

300 47871 05672 0

Power Tower (36 units)

20 x 24 x 35.5 (incl. pallet) 18lbs

3

3

18lbs

5" alarm

1.79"

5.6" w/trim

1016 Corporate Park Drive
Mebane NC 27302
1-800-880-6788
www.kidde.com

Distributed by:

P/N: KL-0918 sheet

rev. 01-2009

Advertising