Cleaning the imaging guides, Cleaning the paper path – Kodak i250 User Manual

Page 28

Advertising
background image

A-61167 September 2002

23

5. Push against the raised edge on the left side of the rear roller cover and

pull the cover up and out to remove it.

6. Remove any dust or debris under the rear roller cover.

7. Re-install the rear roller cover.

8. Go to the next section to clean the imaging guides.

Cleaning the
Imaging Guides

1. Wipe the upper and lower imaging guides with a Staticide Wipe.

2. Dry the imaging guides with a lint-free cloth.

3. Close the scanner door firmly.

4. Go to the next section to clean the paper path.

Cleaning the Paper Path

1. Remove the wrapping from the Transport Cleaning Sheet.

2. Adjust the paper feeder guides to fit the cleaning sheet.

3. Feed the cleaning sheet (adhesive side up) through the scanner in portrait

orientation until all residue is removed from the drive rollers.

4. Adjust the feeder guides to fit, then feed the cleaning sheet (adhesive side

up) through the scanner in landscape orientation until all residue is
removed from the drive rollers.

5. Using the same cleaning sheet, repeat Steps 3 and 4, but feed the

cleaning sheet through the scanner with the adhesive side down until all
residue is removed from the drive rollers.

NOTE: When a cleaning sheet gets very dirty, discard it and use a new one.

Rear roller cover

Advertising