Troubleshooting (cont.)

Symptoms

Probable Causes

Recommended Action

C.

Not enough water in whirlpool.

C.

Fill whirlpool so water level

sensors are covered.

D.

User keypad does not work.

D.

Replace user keypad.

E.

Power from pump motor to

control is off.

E.

Check for loose connections or

wires leading from pump motor to

control.

F.

Backjet pipe is blocked.

F.

Remove blockage.

G.

Switch wire from switch to

control is disconnected.

G.

Reconnect or replace switch wires

that use modular plug.

19.

Backjets do not pulse.

A.

Pulse cannister does not work.

A.

Check for loose connections or

wires leading from pulse cannister

to control. Replace pulse canister or

control if necessary.

Troubleshooting the Effervescence Jets

Symptoms

Probable Causes

Recommended Action

20.

Effervescence ports do not

work.

A.

Whirlpool pump is not

operating.

A.

Turn on pump.

B.

Butterfly valve does not work.

B.

Replace butterfly valve.

C.

Pump does not work.

C.

Refer to the Service Manual to

troubleshoot the system.

D.

Control does not work.

D.

Replace control.

21.

Effervescence ports do not

bubble.

A.

Air intake on suction line is

blocked.

A.

Remove blockage.

B.

Water flow is too low.

B.

Increase water flow.

Troubleshooting the Chromatherapy Lights

Symptoms

Probable Causes

Recommended Action

22.

Chromatherapy lights do

not work.

A.

Loose, disconnected or damaged

wiring/connections.

A.

Check wiring for proper

connections. Replace wiring if

necessary.

B.

Control does not work.

B.

Replace control.