Test Equipment Required for Alignment

Test Equipment

Major Specifications

1. Standard Signal Generator

Frequency Range

400 to 520MHz

(SSG)

Modulation

Frequency modulation and external modulation

Output

0.1

µV to greater than 1mV

2. Power Meter

Input Impedance

50

Operation Frequency

400 to 520MHz or more

Measurement Capability

Vicinity of 50W

3. Deviation Meter

Frequency Range

400 to 520MHz

4. Digital Volt Meter

Measuring Range

1 to 20V DC

(DVM)

Accuracy

High input impedance for minimum circuit loading

5. Oscilloscope

DC through 30MHz

6. High Sensitivity

Frequency Range

10Hz to 600MHz

Frequency Counter

Frequency Stability

0.2ppm or less

7. Ammeter

13A or more

8. AF Volt Meter

Frequency Range

50Hz to 10kHz

(AF VTVM)

Voltage Range

3mV to 3V

9. Audio Generator (AG)

Frequency Range

50Hz to 5kHz

Output

0 to 1V

10. Distortion Meter

Capability

3% or less at 1kHz

Input Level

50mV to 10Vrms

11. Voltmeter

Measuring Range

10 to 1.5V DC or less

Input Impedance

50k

Ω/V or greater

12. 4

Ω Dummy Load

Approx. 4

Ω, 20W

13. Regulated Power Supply

13.6V, approx. 20A (adjustable from 9 to 20V)

Useful if ammeter requipped

1

8

1 : BLC
2 : +B
3 : GND
4 : PTT/TXD
(PC serial data
from radio)

MIC connector (Front panel view)

5 : MICE
6 : MIC
7 : HOOK/RXD
(PC serial data
to radio)
8 : DM

Test cable for microphone input (E30-3360-08)

3

2

4

5

6

7

8

3

1

2

4

5

6

7

8

1

GREEN

RED

BLACK

BLUE

SHIELD

WHITE

GRAY

YELLOW

PTT

E

MIC-E

MIC

HK

Tuning cable (E30-3383-05)

Adapter cable (E30-3383-05) is
required for injecting an audio if
PC tuning is used.
See “PC Mode” section fot the
connection.

Lead wire +

MIC

Shield wire –

ADJUSTMENT

to transceiver

to VGS-1

Check Jig for the VGS-1