Error Codes

In the event of a problem, the power status indicator (2) will flash error code(s) in

red. Errors are identified by a sequence of 3, 4, or 5 flashes. There is a pause

between codes, and in the case where there is only one error code, the same

code is repeated.

Diagnostic Code

Possible Condition

Course of Action

3 flashes

Excessive current draw

Check loudspeaker and

cables for short circuits.

If you are driving more

than one loudspeaker

per channel, check that

the combined load does

not drop below 2 Ohms.

The power breaker

switch must be shut off

to reset the fault condi-

tion.

4 flashes

Excessive temperature

Allow the amplifier to

cool, and increase venti-

lation. If the problem

persists, please call the

factory.

5 flashes

Excessive DC at input

Check the preamplifier

output and source out-

puts for excessive DC

voltage.

If you are using a vacuum

tube preamplifier, use

only the single-ended

inputs, as they are

capacitor coupled.