Thank You for purchasing a Kenmore water heater. Properly
installed and maintained, it should give you years of trouble free
service. If you should decide that you want the new water heater
professionally installed by Sears call 1-800-4-MY-HOME

®

. They

will arrange for prompt, quality installation by Sears authorized
contractors.

Abbreviations Found In This Instruction Manual:

• CSA - Canadian Standards Association

• ANSI - American National Standards Institute

• NFPA - National Fire Protection Association

• ASME - American Society of Mechanical Engineers

• GAMA - Gas Appliance Manufacturers Association


• This gas-fired water heater is design certified by CSA

INTERNATIONAL under American National Standard/CSA
Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1
(current edition).

• Read the “Safety Precautions” section, page 3 of this manual

fi rst and then the entire manual carefully. If you don’t follow
the safety rules, the water heater will not operate properly. It
could cause DEATH, SERIOUS BODILY INJURY AND/OR
PROPERTY DAMAGE.

This manual contains instructions for the installation, operation,
and maintenance of the gas-fi red water heater. It also contains
warnings through out the manual that you must read and be
aware of. All warnings and all instructions are essential to the
proper operation of the water heater and your safety. Since
we cannot put everything on the fi rst few pages, READ THE
ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR
OPERATE THE WATER HEATER.

• The installation must conform with these instructions and the

local code authority having jurisdiction. In the absence of local
codes, installations shall comply with the following:

The National Fuel Gas Code ANSI Z223.1/NFPA 54. This
publication is available from the Canadian Standards
Association, 8501 East Pleasant Valley Rd, Cleveland
Ohio 44131, or The National Fire Protection Association,
1 Batterymarch Park, Quincy, MA 02269.

• If after reading this manual you have any questions or do

not understand any portion of the instructions, call the Sears
Service Center.

• Carefully plan the place where you are going to put the

water heater. Correct combustion, vent action, and vent
pipe installation are very important in preventing death
from possible carbon monoxide poisoning and fi res. See
fi gure 1.

Examine the location to ensure the water heater complies

with the Facts to Consider About the Location section in this
manual.

• For California installation this water heater must be braced,

anchored, or strapped to avoid falling or moving during
an earthquake. See instructions for correct installation
procedures. Instructions may be obtained from your local
dealer, wholesaler, public utilities or California Offi ce of the
State Architect, 400 P Street, Sacramento, CA 95814.

• Massachusetts Code requires this water heater to be installed

in accordance with Massachusetts 248-CMR 2.00: State
Plumbing Code and 248-CMR 5.00.

CUSTOMER RESPONSIBILITIES

PRODUCT SPECIFICATIONS

RECOVERY MINIMUM

DIMENSIONS

TANK

TYPE

INPUT

RATE GALS.

VENT PIPE

DIAMETER IN INCHES (mm)

CAPACITY

OF

RATE

PER

HOUR

INCHES

INCHES

HEIGHT

TO

MODEL NUMBER IN GALS (LTRS)

GAS

(Btu/hr)

@ 90°F RISE

(mm)

(mm)

JACKET TOP

153.334430

40 (151)

NATURAL

40,000

45.8

3” (76) or 4” (102) 20 1/2” (521)

55 1/2” (1,410)

153.334530

50 (189)

NATURAL

40,000

45.8

3” (76) or 4” (102)

22” (558)

56 1/2” (1,435)

Advertising