Appendix d - startup data sequence, Vided in, Appendix d – KVH Industries TracVision C3 User Manual

Page 70: Appendix d startup data sequence

Advertising
background image

Appendix D
Startup Data Sequence

The data on the following pages presents a standard startup data
sequence registered by the TracVision C3. This sequence can be
recorded using the data port and a PC.

?PGM

KVH TracVision C3 Rev X - Version X.XX - Serial Number XXXXXXXX

RF: ZAP

*** Initializing RF Controller ***

RF: S,A,V,U,V

RF: SATINSTALL,55,C,57,C

RF: L,A-------------------------------------------Identifies Satellite A or B as currently

RF: SATCONFIG loaded for acquisition

RF: F,A,12368,20000,67,0X0000,V,U,2---------------Satellite Configuration data, Satellite A

RF: F,A,12368,20000,67,0X0000,V,U,2

RF: F,A,12238,20000,67,0X0000,H,U,2

RF: F,A,12238,20000,67,0X0000,H,U,2

RF: F,B,12374,20000,34,0X1004,V,U,3---------------Satellite Configuration data, Satellite B

RF: F,B,12374,20000,34,0X1004,V,U,3

RF: F,B,12381,20000,34,0X1004,H,U,3

RF: F,B,12381,20000,34,0X1004,H,U,3

RF: RF PCB Version X.X----------------------------Current RF software revision

RF: I,0,49568,00000,00196,0

RF COMM: PASS-------------------------------------PASS is expected

*** Initializing Antenna ***

GPS: UTC: 083000.00, Lat: 4131.00N, Long: 7115.00W

GPS: DSS_119 AZ = 238.9, EL = 22.1

GPS: DSS_101 AZ = 220.9, EL = 33.4

Limit Switch Test

Limit Switch Status: PASS-------------------------PASS is expected

*** Initializing Rate Bias ***

+A/D: 1994 2029 329

RF: S,A,V,U,V

+A/D: 1994 2029 418

RF: S,A,H,U,V

+A/D: 1995 2028 267

RF: S,A,V,U,V

+A/D: 1995 2029 401

RF: S,A,H,U,V

+A/D: 1993 2029 290

RF: S,A,V,U,V

+A/D: 1994 2030 432

Gyro Bias: Az = 1994.01, El = 2029.16-------------Expected range is 1700-2300

Gyro Uncertainty: Az = 3.00, El = 3.00

D-1

Startup Data Sequence

54-0159 Rev. G

Advertising