ELECTRICAL TESTING

Electrical test
Before assemby all electrical parts MUST be checked for safety, and that they conform to specification.

Testing the Armature (Flash Testing)

A

Armature shaft to lamination pack

1500 Volts (min)

B

Lamination pack to commutator

1200 Volts (min)

C

Armatuure shaft to commutator

3000 Volts (min)

ELECTRICAL PERFORMANCE TEST READINGS

CLUTCH SLIP

Measured on disassembly/assembly 35/45ft lbs 47/61Nm. (Non Electrical Test)
Note: On all test readings + or -5% of figures shown is acceptable.

845S

845S

MODEL

110V

120V

220V-240V

ARMATURES

.440/.506 Ohms

.440/.506 Ohms

1.283/1.477 Ohms

FIELD COILS

845S

110V

120V

220V-240V

4.5/6.5 Amps

4.5/6.5 Amps

2.9/4.4 Amps

.349/.401 Ohms

.349/.401 Ohms

1.339/1.54 Ohms

PERFORMANCE

110V

120V

220V-240V

Running No Load

Advertising