RS-232 Status Feedback Description
for the Home Theater Standard 7.1

RS-232 Status Block Descriptions
for the Home Theater Standard 7.1

The Home Theater Standard 7.1 reports its operational status by trans-
mitting a block of status data via the RS-232 connector. The block is
configured as eighteen 8-bit words. The first and last word always con-
tains hexadecimal code 55 to facilitate message framing and synchro-
nization. When the data block is sent through an RS-232 port, each
8-bit word transmitted will also have 1 stop bit associated with it. The
exact RS-232 protocol settings for both status and Home Theater
Standard 7.1 control are as follows:

9600 Baud 8 Data Bits 1 Stop Bit No Parity

The feedback system is available only through the RS-232 connector.
The status can be activated in two ways. The first is to ask for status to
be sent by sending the RS-232 command code "STAZ". The second is
to enable auto status by sending the RS-232 command code "ASTEZ".
Once the auto status command is sent, the Home Theater Standard 7.1
will transmit a status block whenever the status changes. Auto status is
disabled by sending the RS-232 command code "ASTDZ". Auto status
remains enabled until AC power is removed or turned off. When AC
power is reapplied, auto status is disabled.

Word 1: Start of Message

Bit

Description

Bit 7 – 0:

Hexadecimal 55

Word 2: General Status I

Bit

Description

Bit 7:

System Mute

1 = Internal mute is active

Bit 6:

Main Mute

1 = Main mute is active

Bit 5:

Zone 2 Mute

1 = Zone 2 mute is active

Bit 4:

Current Zone

1 = Zone 2 is active

All numeric values described in the following charts are decimal values
unless otherwise noted. The description of the eighteen 8-bit words
follow.

The values marked

Reserved

must be ignored during pattern matching.

7

6

5

4

3

2

1

0

0

1

0

1

0

1

0

1

Krell Home Theater Standard 7.1 Developer’s Reference

11

7

6

5

4

3

2

1

0

System Mute

User Mute

Zone 2 Mute

Current Zone

Input Trigger

Zone 2 Only

Zone 2 Power

Main Power

Bit 3:

Input Trigger

1 = 12V input trigger is active

Bit 2:

Zone 2 Only

1 = Only Zone 2 power is on

Bit 1:

Zone 2 Power 1 = Zone 2 power is on

Bit 0:

Main Power

1 = Main power is on