Head Height Alignment Procedure

Perform this procedure only when the encoder strip stabilizer has been

removed from the Y-Arm or whenever the alignment is in question.

The head height alignment procedure is to ensure that the correct

amount of distance exists between the cartridge jet plate and the Platen.

See Figure 3-14.

HEAD HEIGHT

CARTRIDGE
JET PLATE

PLATEN

Figure 3-14. Carriage Head Height Tolerance.

1. Remove the lid and the right cover of the printer. See Chapter 5

for procedures.

2. Obtain the 3 tools (Micrometer Dial Gauge, Test Cartridge, and

Measuring Tip Extender) from the Height Gauge Kit. Assemble

the tools as shown in Figure 3-15.

SPIN HEAD ON

MICROMETER GAUGE

TO FACE BACKWARDS

TIGHTEN SET

SCREWS

ENSURE TIP EXTENDS

BELOW CARTRIDGE

1/4" (6mm)

MICROMETER
DIAL GAUGE

TEST CARTRIDGE

MEASURING
TIP EXTENDER

Figure 3-15. Setting Up Tools from Height Gauge Kit.