Specifications – Kidde KN-COPP-3-RC User Manual

Page 28

Advertising
background image

Specifications

Power:

120 V AC units: 60 Hz, Current 60 mA max.

Sensor:

Sensor calibrated at 150 ppm (±25 ppm).

Temperature:

Operating range: 4.4˚C (40˚F) to 37.8˚C (100˚F).

Humidity:

Operating range: 5–95% non-condensing.

Mounting:

Accessories supplied for wall mount, direct plug and tabletop appli-
cations.

Alarm:

85+ dB at 3 m (10') @ 3.4 ± 0.5 KHz pulsing alarm.

CO Alarm Time:

At 70 PPM, the unit must alarm within 60–240 minutes.
At 150 PPM, the unit must alarm within 10–50 minutes.
At 400 PPM, the unit must alarm within 4–15 minutes.

Digital Display Accuracy:

Each Carrier CO Alarm is calibrated at a CO concentration of
150 ppm in air, at 80˚ F (+/- 10˚ F). Depending on the ambi-
ent condition (temperature, humidity) and the condition of the
sensor, the alarm readings may vary.

The digital reading tolerances are:
Ambient: 80˚ F (+/- 10˚ F), atmospheric pressure +/- 10%,
40% +/- 3% relative humidity.

Tolerance

Reading

(of displayed reading)

0-999 ppm

+/-20% +15 ppm

Depending on the ambient condition (temperature, humidity)
and the condition of the sensor, the alarm readings may vary.

24

Advertising