Product data sheets, Base grille water filtration system – KITCHENAID 2302428 User Manual

Page 17

Advertising
background image

17

PRODUCT DATA SHEETS

Base Grille Water Filtration System

Model WF-L200V Capacity 200 Gallons (757 Liters)

Model WF-NL120V Capacity 120 Gallons (454 Liters)

This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in ANSI/NSF 42/53.

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F
(17.2°C).

It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.

Model WF-L200V: The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter’s rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter’s rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the filter. Use replacement cartridge L200V /NL120V,
part #4396701. 2005 suggested retail price of $32.99 U.S.A./
$49.99 Canada. Prices are subject to change without notice.

Model WF-NL120V: Change the water filter cartridge every 6-
9 months. Use replacement cartridge L200V / NL120V, part
#4396701. 2005 suggested retail price of $32.99 U.S.A./
$49.99 Canada. Prices are subject to change without notice.

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.

Refer to the front cover or “Accessories” section for the
Manufacturer’s name, address and telephone number.

Refer to the “Warranty” section for the Manufacturer’s limited
warranty.

Application Guidelines/Water Supply Parameters

Substance Reduction
Aesthetic Effects

NSF Reduction
Requirements

Average
Influent

Influent Challenge
Concentration

Maximum
Effluent

Average
Effluent

Minimum%
Reduction

Average%
Reduction

Chlorine Taste/Odor
Particulate Class lll

*

50%

85%

1.9 mg/L
49333/mL

2.0 mg/L ± 10%
At least 10,000 particles/mL

0.07 mg/L
640/mL**

0.06 mg/L
312/mL

>75%
98.7%

>75%
99.0%

Contaminant
Reduction

NSF Reduction
Requirements

Average
Influent

Influent Challenge
Concentration

Maximum
Effluent

Average
Effluent

Minimum%
Reduction

Average%
Reduction

Lead:@ pH 6.5
Lead: @ pH 8.5

0.01mg/L
0.01mg /L

0.14 mg/L

0.15 mg/L

0.15 mg/L ± 10%
0.15 mg /L ± 10%

0.0014 mg/L
0.0069 mg/L

0.0011 mg/L
0.0042 mg/L

99.00%
95.40%%

99.21%
97.20%

Mercury: @ pH 6.5
Mercury: @ pH 8.5

0.002 mg/L
0.002 mg/L

0.0059 mg/L
0.0054 mg/L

0.006 mg/L ± 10%
0.006 mg /L ± 10%

0.0009 mg/L
0.0007mg /L

0.0004 mg/L
0.00043 mg/L

84.74%
87.03%

93.22%
92.03%

Benzene

0.005 mg/L

0.0157 mg/L

0.015 mg/L ± 10%

0.002 mg/L

0.00083 mg/L

87.26%

94.71%

p-dichlorobenzene

0.075 mg/L

0.210 mg/L

0.225 mg/L ± 10%

0.0005 mg/L

0.0005 mg/L

99.76%

99.76%

O-Dichlorobenzene

0.60

1.84

1.8 ± 10%

0.20

0.0418

89.13

97.73

Toxaphene

0.003

0.0143

0.015 ± 10%

0.0012

0.0010

91.60

93.00

Ethyl Benzene

0.70

2.00

2.1 ± 10%

0.40

0.085

80.00

95.75

1,2,4- trichlorobenzene 0.07

0.232

0.21 ± 10%

0.0041

0.0016

98.23

99.31

System tested and certified by NSF International against NSF/ANSI
Standard 53 for the reduction of Lead, Mercury, Benzene,
p-dichlorobenzene, O-Dichlorobenzene, Toxaphene, Ethyl Benzene,
1,2,4-trichlorobenzene and against NSF/ANSI Standard 42 for the
reduction of Chlorine Taste and Odor and Particulate Class III.

Water Supply
Water Pressure
Water Temperature
Service Flow Rate

City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 GPM (1.9 L/min.) @ 60 psi.

*

**

Class Ill particle size: > 5 to < 15 um
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.

® NSF is a registered trademark of NSF International.

Advertising