background image

HD 4000 C / HD 6000 C

English

5.956-648 A10369 (06/98)

F4

System runs for about 15
sec after pressing the
unlock button and then
switches off. General fault
and “Admission pressure
of hot-water pump too low”
LED light up

Admission pressure of
hot water too low

check pump rotation
direction, check water
intake

Customer
Service

Pressure switch
precompression
hot-water pump or
cable in ABS hot
water defective

replace

Customer
Service

Pump starts during
available time but not by
opening the handgun

Pressure switch or
cable to pressure
switch defective

replace

Customer
Service

Unlock button activated,
“operational” indicator light
illuminates, system does
not start up

Pressure switch
defective

replace

Customer
Service

While activating the HD
pistols the unit switches
itself off

Flow switch does not
function

check flow switch

Customer
Service/
Electrician

Unlock button activated,
system starts up,
“operational” indicator light
does not illuminate

“operational” indicator
light defective

switch Emergency-STOP
master switch Q1 to
position 0, open control
cabinet and verify or
replace components

Customer
Service/
Electrician

System does not switch on Flow switch S2

defective

replace upper part of flow
switch

Customer
Service/
Electrician

Remote start button does
not function

System in a
malfunction state

eliminate the cause and
press unlock button

Operator

F. Trouble Shooting

Advertising