10

FILTER CARTRIDGE / USEFUL LIFE / REPLACEMENT (cont.)

Note: If the sump will not tighten up to the head, you

may have the cartridge in upside down. Take the carĆ

tridge out and check for correct orientation.

TURN
SUMP
COUNTER-
CLOCKWISE
TO TIGHTEN

sump

cartridge

head

o–ring
seal

vent valve

7. Being careful not to cross-thread, turn the sump

onto the filter head and tighten securely.

8. Partially open a house faucet on the outlet side of

the filter housing. Then, slowly open the water supĆ

ply shutoff valve and allow the filter housing to fill.

While it is filling, press the filter vent valve to release

air in the filter.

9. Close the house faucet. Then, check for leaks beĆ

tween the sump and the head.

Note: If leaking, turn off the water supply and depresĆ

surize the filter. Then, disassemble the filter and check

the o-ring for cuts, flat spots, etc., and sealing surfaces

for foreign material. Relubricate the o-ring with siliĆ

cone grease or Vaseline and carefully press into the

groove in the sump.

Advertising