Fire Sentry

Battery Operated 4” Smoke Alarm

Model i9040

Technical Specifications

Model Number:

i9040

Power Source:

9V Battery (included)

Audio Alarm:

85dB at 10ft

Temperature Range: 40˚F to 100˚F (4°C to 38°C)
Humidity Range:

up to 85% relative humidity (RH)

Sensor:

Ionization

Size:

4” in diameter x 1.45” depth

Weight:

.5lbs

Interconnects:

No

Warranty:

3 year limited

**Not for sale by individual unit

Ordering

Pack

Pack

Dimensions

Case

Cases per

Number

UPC

I 2 of 5

Confg. Quantity

(w x d x h inches)

Weight

pallet

0914

0-25417--00914-9

200-25417-00914-3 BOX

Cut Case (12 Units)

6.60 x 13.00 x 4.60

4.55 lbs

168

0914-9960 0-25417--91460-3

200-25417-91460-7 BOX

Cut Case (8 Units)

10.30 x 10.70 x 7.60

7.30 lbs

84

0914-040

0-25417--91422-1

300-25417-91422-2 BOX

Cut Case (40 Units)

9.00 x 17.00 x 9.00

15.00 lbs

30

0914T-020 0-25417--91422-1

200-25417-91422-5 BOX

Cut Case (20 Twin Packs) 9.00 x 17.00 x 9.00

15.00 lbs

60

0914E

0-25417--09145-8

200-25417-09145-2 BOX

Master Pack (12 Units)

10.10 x 10.10 x 5.10

5.20 lbs

112

1016 Corporate Park Drive
Mebane NC 27302
1-800-880-6788
www.kidde.com

Distributed by:

KL-i9040 sheet

Rev. 1-12-09

Architectural and Engineering
Specifications

The smoke alarm shall be Kidde Model Number i9040

or approved equal. It shall be powered by a 9V battery.
The unit shall incorporate an ionization smoke sensor
with nominal sensitivity of 0.52-1.12%/ft. The tempera-
ture operating range shall be between 40°F and 100°F
(4°C and 38°C) and the humidity operating range shall
be up to 85% relative humidity.

The alarm can be installed on the surface of any wall

or ceiling following the UL/NFPA/Manufacturer’s recom-
mended placement guidelines.

The alarm shall include a test button that will electroni-

cally simulate the presence of smoke an cause the unit
go into alarm. This sequence tests the unit’s electronics,
battery and horn to ensure proper operation.

The unit shall include a piezoelectric horn that is rated

at 85 decibels at 10 feet. The alarm shall produce the
ANSI S3.41 three pulse temporal pattern audible emer-
gency evacuation signal.

The unit shall also indicate a low battery warning utiliz-

ing a brief alarm chirp ever 30-40 seconds for a minimum
of seven (7) days.

The smoke alarm shall at a minimum meet the require-

ments of UL 217, NFPA 72, The California State Fire
Marshall, NFPA 101 (One and two family dwellings
Federal Housing Authority (FHA). It shall also include a
3-year manufacturer’s limited warranty.