Kohler Marine Generator Sets 11EFOZ/13EOZ User Manual

Page 83

Advertising
background image

TP-6069 6/03

73

Section 8 Reconnection/Adjustments

Stabilizer Potentiometer (Pot) fine tunes the regulator
circuitry to reduce light flicker.

Voltage Adjustment Pot adjusts the generator voltage
output within the range of approximately 100 to 130
volts.

Volts/Hz Pot determines the engine speed (Hz) at
which the generator output voltage begins to drop.

Note: The volts/Hz adjustment does not apply to the

following models:

Model

4/6.5/8/8.5/9EFOZ

5/8/9/10EOZ

Note: On these models, turn the volts/Hz adjustment

pot full counterclockwise to stop and seal. No
further volts/Hz adjustments are required.

Note: For optimum results, apply full load for voltage

regulator adjustment.

Voltage Regulator Adjustment Procedure

1. With the generator set off, turn the remote

rheostat, if equipped, to the midpoint.

2. Turn the voltage, volts/Hz, and stability pots fully

counterclockwise.

3. Connect the voltmeter and frequency meter to the

AC circuit or an electrical outlet.

4. Start the generator set.

5. Rotate the voltage adjustment pot clockwise to

increase

the

voltage

(counterclockwise

to

decrease voltage) to achieve the desired output
voltage.

6. Rotate the stability pot clockwise to minimize light

flicker.

7. Readjust the voltage adjustment pot if necessary.

8. Adjust the engine speed to the desired cut-in

frequency (factory setting 57.5–58 Hz for 60 Hz
models or 47.5–48 Hz for 50 Hz models) as
measured on frequency meter. To change engine
speed adjust the governor arm.

Loosen the

locknut and turn it clockwise or counterclockwise
to

achieve

the

desired

frequency.

See

Figure 8-13. If a second screw holds the governor
arm, loosen the locknut and back out the screw.

9. If applicable, rotate the volts/Hz adjustment pot

clockwise until the voltage level begins to drop (as
measured on the voltmeter). When set to these
specifications, the generator attempts to maintain
normal output until the engine speed drops below
the frequency set in step 8 as load is applied.

10. Readjust the engine speed to normal (63 Hz/

1890 rpm for 60 Hz or 52.5 Hz/1575 rpm for
50 Hz). Tighten the locknut when the adjustments
are complete. Turn the second screw, if used, to
lock the governor arm in place and tighten the
locknut.

11. Readjust the voltage adjustment pot if necessary.

12. Readjust the stability pot if necessary.

13. Use the remote rheostat, if equipped, to make final

voltage adjustments.

14. Stop the generator set.

1-929

1

2

1. Locknut
2. Speed adjusting screw

Figure 8-13 Governor Adjustment (4EFOZ/5EOZ

shown)

Advertising