18.

Bring the electrical cables into the case.

19.

Strip back sufficient of the outer cable insulation to enable routing to terminal
block.

20.

Fit an earth sleeve to the earth wire.

21.

Loosen the screws in the terminal block and insert the bare wires into the clamps.

L (Live) = Brown wire

T

(Earth) = Green sleeved wire

N (Neutral) = Blue wire

Note!

Do not twist the cores of the wires or strain the cables to make them reach

the terminal block.

22.

Connect the conductors firmly into the terminal block. Make sure that the bare
cores of each conductor are securely trapped within each conductor clamp.

L

N

Electrical
Cables

Terminal Block

Outlet
Connector