SERVICE TECH. INFORMATION

SECTION 5

22

5A.

TROUBLESHOOTING

WATER METER TURBINE: With soft water in use,

the turbine flow rate display continually repeats a

000 to 199 count for each gallon of water passing

through the turbine. The display will remain a

steady¼ 000 if soft water is not in use (open a

nearby soft water faucet to check).

If you don’t get a reading in the display, with

facuet open, pull the sensor from the valve outlet

port. Pass a small magnet back and forth in front of

the sensor. You should get a reading in the display.

If you get a reading, unhook the in and out

plumbing and check the turbine for binding.

VALVE POSITION INDICATORS: Depending on the

valve position, the following indicators show in

the display:

INDICATOR

VALVE POSITION

Serv

service

Fill

fill

Brine

brining/brine rinse

Bkwash

backwash

Rinse

fast rinse

When the valve is rotating from 1 cycle to another,

both indicators flash. For example, if the valve is in

transition between fill and brining, both Fill and

Brine flash. Upon reaching brining position, Fill

goes off and Brine is on steady. The time display

shows the minutes of the cycle remaining.

NOTE: If the face plate is left in a diagnostic display

(or a flashing display when setting times or

hardness), present time automatically returns if a

button is not pressed within 4 minutes. To return to

the diagnositc display, repeat step 2.

OTHER INFORMATION: While in this diagnostic

screen, the following information is available and may

be beneficial for various reasons. This information is

retained by the computer from the first time electrical

power is applied to the face plate.
¼ Press

to display the number of days this face

plate has had electrical power applied.
¼ Press

to display the number of regenerations

initiated by this face plate since the AR code

number was entered.

3.

Press the #1 SELECT button and hold 3

seconds until¼

This code identifies the softener nominal capacity

size. If the wrong number shows, the softener will

operate on incorrect programming. Do the

following as needed.

AR31 does show — Press the #1 SELECT button

to return the present time display.

To change AR number — press the or button

until AR31 shows. The, press the #1 SELECT

button and reset the timer¼ page 6.

FACE PLATE REPLACEMENT: BE SURE

THE VALVE IS IN SERVICE POSITION (OB-

SERVE VALVE CYCLE INDICATOR) WHEN

REPLACING THE FACE PLATE.
If, after installing and

programming the re-

placement face place,

the valve is not in ser-

vice position, do the fol-

lowing to assure correct

cycle orientation, or tim-

ing, between the face

plate and valve.
Use the MANUAL ADVANCE procedures,

page 23. With the RECHARGE NOW button,

advance through the recharge cycles until the

valve stops in service position, and RE-

CHARGE no longer flashes in the timer.
NOTE: The valve motor may automatically

drive through several valve positions while

searching for service. If an error code occurs,

unplug the transformer, then plug in again.