How to record (ct-203/kxf-w4010; deck b only), Normal recording, Preparation – Kenwood KXF-W6010 User Manual

Page 16: Set the recording level, Select the source to be recorded

Advertising
background image

CT-2050/203/KXF-W6010/W4010 (En/M)

16

Each press of the MODE key changes the setting.

1

“LEVEL” lights up: Recording level setting mode

2

“BAL.” lights up: Recording balance setting mode

3

“BIAS” lights up: Recording bias setting mode (Deck B of the

CT-2050/KXF-W6010 only)

4

“LEVEL”,“BAL.”,and “BIAS”go off: Counter display mode

Set the recording level.

÷ Adjust the recording level so that the 0 dB of the peak level indicators

sometimes lights up.

÷ The recording level can be adjusted on both decks A and B. (CT-203/

KXF-W4010; Deck B only)

lights up

lights up

The cassette deck incorporates the Dolby HX Pro headroom
extension function and auto-bias function to provide a re-
cording with superior high-frequency characteristics.
Since this unit is not designed for recording with metal
(TYPE

) tapes, do not use metal tapes for recording.

How to record (CT-203/KXF-W4010; Deck B only)

Preparation

÷ Select by operating the input selector of the amplifier (optional).

÷ In case of recording a FM broadcast,refer to discription of "How to use

the MPX FILTER key".

&

÷ While pressing the PAUSE (8) key, press the REC/ARM (¶) key.

0dB.

Recording level display.

1

Make “Playback (recording) preparation”.

0

(CT-203/KXF-W4010; Insert a tape in deck
B.)

2

(Load a disc in the CD player.)

: Keys and control used in the operations described on this page.

Normal recording

1

Select the source to be recorded.

3

2

Perform auto-bias adjustment. (The bias adjustment is applied to deck B.)

AUTO BIAS

÷ The optimum bias is set in about 40 seconds, after which the deck

enters the stop mode.

÷ For a fine adjustment after setting AUTO BIAS, refer to the description

of “Bias level adjustment”. (CT-2050/KXF-W6010 only)

&

÷ To cancel the auto-bias adjustment operation in the middle, press the

stop (

7) key.

÷÷÷÷÷Recording is possible even when the auto-bias setting is omitted.

÷ If the amount of remaining tape is small, the auto-bias adjustment may

be canceled in the middle and tape stopped at that position.

÷ The bias level is canceled when the eject (0) key is pressed.

1

Play a music source.

2

Enter the record-pause mode.

8

PAUSE

REC/ARM

3

Press the MODE key and select the "BAL."
mode.

MODE

4

Adjust the recording balance.

REC LEVEL/BAL.
/BIAS

MAX/R

MIN/L

Right sound
decreases.

Left sound
decreases.

5

Press the MODE key and select the
"LEVEL" mode.

MODE

6

Adjust the recording level.

REC LEVEL/BAL.
/BIAS

MAX/R

MIN/L

Recording
level
decreases.

Recording
level
increases.

7

Stop playing the source.

÷ In counter, adjust the recording balance level so that the left and right

displays are the same. You can also check with the Ò and  peak level
indicators.

Right channel level

Left channel level

CT-2050/KXF-W6010

CT-203/KXF-W4010

CT-2050/KXF-W6010 only

“AUTO BIAS”blinks.

After approximately
40 seconds

“AUTO BIAS” lightsup.

Each press of the MODE key changes the setting.

1

“LEVEL” lights up: Recording level setting mode

2

“BAL.” lights up: Recording balance setting mode

3

“BIAS” lights up: Recording bias setting mode (Deck B of the

CT-2050/KXF-W6010 only)

4

“LEVEL”,“BAL.”,and “BIAS”go off: Counter display mode

Advertising
This manual is related to the following products: