6. Align the telescopic stack to the pre-drill

holes on the ceiling and securely fasten to
the joists and cross framing lumber with
eight screws (not provided). Make sure
screws are driven into center of joists and
cross framing lumber for maximum support.

7. Adjust the blower unit to the telescopic

stack using reference F calculated in
TABLE 1 on page 4 and measurements on
pages 14-15. Tighten blower unit to the
telescopic stack with four

(M5 x 15) screws

(provided) as shown in Figure 4.

SAFETY WARNING

RISK OF ELECTRICAL SHOCK. THIS
RANGE

HOOD

MUST

BE

PROPERLY

GROUNDED. MAKE SURE THIS IS DONE
BY

QUALIFIED

ELECTRICIAN

IN

ACCORDANCE WITH ALL APPLICABLE
NATIONAL

AND

LOCAL

ELECTRICAL

CODES. BEFORE CONNECTING WIRES,
SWITCH POWER OFF AT SERVICE PANEL
AND LOCK SERVICE PANEL TO PREVENT
POWER FROM BEING SWITCHED ON
ACCIDENTALLY.

8. Route house wiring into the ceiling as close

to the installation location as possible.
Allow additional length to drop down from
the ceiling to the electric box.

9. Connect the electrical wires according to

color (green to green, white to white, and
green to green) and cap with wire
connectors as shown in Figure 5. Green
wire must be grounded to reduce risk of
electric shock.

Ductwork Installation

10. Use 7” round aluminum or steel pipe (not

provided) to connect the 7” round damper
on the hood to the ductwork above. NOTE:
Place 7” round duct pipe over the damper.
Seal with duct tape to make all joints secure
and air tight. NOTE: MAKE SURE FLAPS
ON DAMPER CAN OPEN & CLOSE
FREELY. (Figure 6)

Figure 4













Figure 5













Figure 6













Telescopic Stack Installation

Wiring to Power Supply

Advertising