Safety warning, Caution – Kobe Range Hoods IN-027 User Manual

Page 9

Advertising
background image

7

Wiring to Power Supply

SAFETY WARNING

RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD MUST
BE PROPERLY GROUNDED. MAKE SURE THIS IS DONE
BY QUALIFIED ELECTRICIAN IN ACCORDANCE WITH ALL
APPLICABLE NATIONAL AND LOCAL ELECTRICAL
CODES. BEFORE CONNECTING WIRES, SWITCH POWER
OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO
PREVENT

POWER FROM BEING SWITCHED ON

ACCIDENTALLY.

9. Temporarily wire the hood to test for proper operation

before installing. If the insert does not operate, check
the circuit breaker or house fuse. If the insert is still not
working, disconnect the power supply and check the
continuity of all wiring connections.

10. Connect electrical wires.
11. Connect three wires (black, white and green) to house

wires and cap with wire connectors. Connect wires
according to their colors (i.e. black to black, white to
white, and green to green). See Figure 3.

12. Store wires in the wiring box.
13. Determine the proper location for the Power Supply

Cable. Make a wiring access hole using a drill bit.
Install the wire cable and seal the gap around hole.
Note: Connect all electrical wires before installing insert.
DO NOT turn on the power until installation is complete.

Duct Work Installation

14. Use 6” steel pipe (follow building codes in your area) to

connect the ducting on the hood to the ductwork above.
Use duct tape to seal and secure joints as shown in
Figure 4.

15. Please refer to local codes for the usage of the damper

(included). If necessary, remove the damper
mechanism and install as exhaust connector.

Hood Preparation Before Installation

CAUTION

: If moving the cooking range is

necessary to install the hood, turn off the power in
an electric range at the main electrical box. SHUT
OFF THE GAS BEFORE MOVING A GAS RANGE.

16. Determine and mark the centerlines on the base of the

wood frame where the insert will be installed.

17. Determine and make all necessary cuts in the wall or

ceiling for the ductwork. Note: Install the duct work
before installing the insert.

18. Cut out the opening where the insert will be installed.

(Figure 5)

Figure 4

Figure 5

Advertising