Commissioning

15

Setup-Menu

The basic setting (status of the MSK 25 after switching it on) can be set in
the Setup menu.

Factory Setting on Delivery

Parameter Setting
POWER ON

TV

LNB DC

OFF

LEVEL dBµV
Low Level Mute

ON

Setup Menu Setting

Setup Menu Call-Up

Press [2ndF] and [SETUP].

The particular mode (TV, SAT, FM) is selected and taken-over by
pressing either [1], [2] or [3]. The current setting is retained by pressing
[ENTER.]

1. Setup menu

The following requests appear:

Press either [1] or [2] to switch on/off the LNB voltage supply.

Press [ENTER] to retain the current setting.

2. Setup menu

Press either [1] or [2] to determine the measurement unit the level is to
be displayed with.

Press [ENTER] to retain the current setting.

3. Setup menu

Set or offset the mute function by pressing either [1] or [2]. Select „ON“ to
mute the MSK 25 until the input signal on the RF input exceeds
30 dBµV.

4. Setup menu

Press [ENTER] to retain the desired setting.

Unless the factory settings have been changed, the indication opposite is
displayed.

Basic setting

After setting the Low Level Mute, the 4th Setup menu will be exitted
automatically and the basic setting will be displayed.

POWER ON
1=TV 2=SAT 3=FM

LNB DC
1=OFF

2=ON

Level
1=dBµV

2=dBmV

LOW LEVEL MUTE
1=OFF

2=ON

CH: .07.

TV

LEV:____.__dBµV

Advertising