DIMENSIONS

8003A

8002A

G 1/2"

124 mm

89 mm

79 mm Min Clearance

67 mm

60 mm

Center of

Water Inlet

All information is based on the latest product information available at the time

of publication. Kohler Co. reserves the right to make changes in product

characteristics, packaging, or availability at any time without notice.

Please leave these instructions for the consumer.

NOTES:

1. Flush the water supply pipes thoroughly to remove any debris.

2. An in line water filter must be used with this product.

3. Inspect the supply pipes for damage. Replace as necessary.

4. Observe local plumbing codes.

5. The recommended working pressure for the shower head is 150KPa to

500KPa. If the pressure exceeds 500KPa a pressure reducer is required.

6. Maximum water and environmental temperature for the shower head is

60C. Note: If a heater is present, make sure to keep it away from the shower

head as otherwise the environmental temperature may exceed 60C.

5IJTQSPEVDUNBZOPUCFTVJUBCMFGPSVTFXJUIDFSUBJOHSBWJUZGFEXBUFS

IFBUFSTPSMPXVOFRVBMQSFTTVSFTVQQMZOFUXPSLT

"MMJOTUBMMBUJPOTTIPVMEDPNQMZXJUISFMFWFOUSFRVJSFNFOUTPG"4/;4

and AS/NZS 6400.

BEFORE YOU BEGIN

SPECIFICATION

Pressures

For multiple outlets an operating pressure of 3.0 bar or greater is

recommended to ensure optimum performance.

Plumbing Connections

(Hot) and Cold (C) inlets must be connected to the

correct inlet supplies.

Building in Depth

Minimum building in depth is 79 mm. It is recommended that

a minimum stud wall cavity of 100 mm is provided to ease installation.