House connection amplifi er return path amplifi er – Kathrein VOS 40/F User Manual

Page 5

Advertising
background image

Type

VOS 30/F

VOS 40/F

Order no.

20910002

20910012

Forward path

Frequency range

MHz

47 (85)-862

Gain (switchable)

dB

24/30

34/40

Amplitude ripple

dB

+/- 1.5

Adjustable attenuator setting range

dB

0-20

Equaliser setting range

dB

0-20

Interstage adjustable attenuator setting range
(can be switched with jumpers)

dB

0/6

Interstage equaliser setting range
(can be switched with jumpers)

dB

-

0/6

Maximum operating level

1)

(60-dB CTB/CSO)

- fl at
- with 6-dB interstage pre-emphasis

dBµV

98/100

-

104/107
106/107

Noise fi gure

dB

7/6

Number of outputs

1

Return path

For data see VGR 28/xx

General

Impedance input/output

75

Return loss input/output

2)

dB

14

RF connections

F connector

Test socket output with directional coupler (5-862 MHz)

dB

-20

Test socket output return path (5-65 MHz)

dB

-20

Supply voltage

V

AC

198-253

Power consumption (without/with return path amplifi er)

W

7/9

6/7

Indication of operation mode

LED green

Protection class

II

Protection class (in accordance with EN 60529)

IP 50

Temperature range

°C

-20 to +55

Dimensions

mm

184 x 134 x 63

Packing unit/weight

pc./kg

1 (10)/1.6

1 (10)/1.4

1)

In accordance with EN 60728-3; CENELEC channel plan 42 carriers

2)

In accordance with EN 60728-3 (category C); from 40 MHz 14 dB-1.5 dB/octave, but 10 dB

936.2763/C/0703/1.4e/ZWT

• House connection amplifi ers for modern HFC networks
• Integrated power supply unit
• Die-cast housing with F connectors
• LED to indicate operation mode
• Gain with interstage attenuation is switchable using jumpers

(delivery condition: high gain)

VOS 40/F: Interstage equaliser (6 dB) can be connected using

jumpers (Pre-emphasis)

• Return path optional, can be confi gured as required:
5-30 MHz with VGR 28/30
5-65 MHz with VGR 28/65
(delivery condition: without return path amplifi er, with jumpers)
• Integrated, variable attenuator and variable equaliser
• Test socket on output -20 dB (with directional coupler)
• Test socket on input -20 dB (can be connected using jumpers) for return path levelling
• Complies with: EN 60728-11, EN 50083-2 and EN 60065
• For indoor installation
• The amplifi ers comply with the requirements in the Low-Voltage Directive 2006/95/EEC and EMC Directive 2004/108/EEC

applicable at the time of shipping.

House connection amplifi er

Return path amplifi er

VOS 30/F 20910002
VOS 40/F 20910012
VGR 28/30 20910008
VGR 28/65 20910009

Advertising
This manual is related to the following products: