PROBLEM

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

BURNER WILL NOT IGNITE

1. Pilot not lit
2. Thermostat set too low
3. No

gas

4. Dirt in the gas lines
5. Pilot line clogged
6. Main burner line clogged
7. Non-functioning

thermocouple

8. Non-functioning

thermostat

9. Heater installed in a confined area

1. Light

pilot

2. Turn temp. dial to desired temperature
3. Check with gas utility company
4. Notify utility-install trap in gas line
5. Clean, locate source and correct
6. Clean, locate source and correct
7. Replace

thermocouple

8. Replace

thermostat

9. Provide fresh air ventilation

SMELLY WATER

1. Sulfides in the water

1. Replace the anode with a special anode

PILOT WILL NOT LIGHT

1. Air in gas line
2. No

gas

3. Dirt in gas lines
4. Pilot line or orifice clogged
5. Cold

drafts

6. Thermostat ECO switch open
7. Non-functioning

igniter

8. Flammable vapor incident

9. Low gas pressure
10. Air for combustion obstructed

11. Pilot dirty

1. Bleed the air from the gas line
2. Check with gas utility company
3. Notify utility-install dirt trap in gas line
4. Clean, locate source and correct
5. Locate source and correct
6. Replace

thermostat

7. Replace igniter pilot assembly
8. Eliminate flammable vapor source(s)
Call

1-800-4-MY-HOME

®

(1-800-469-4663)

9. Check with gas utility company
10. See service and adjustment section for

inspection and cleaning of flame arrestor
& burner

11. Clean pilot

PILOT WILL NOT REMAIN LIT

1. Air in gas line
2. Dirt in gas lines
3. Pilot line or orifice clogged
4. Thermocouple connection loose
5. Non-functioning

thermocouple

6. Cold

drafts

7. Flammable vapor incident

8. Low gas pressure
9. Air for combustion obstructed

10. Pilot dirty

1. Bleed the air from the gas line
2. Notify utility-install dirt trap in gas line
3. Clean, locate source and correct
4. Finger tighten; then 1/2 turn with wrench
5. Replace

thermocouple

6. Locate source and correct
7. Eliminate flammable vapor source(s)
Call

1-800-4-MY-HOME

®

(1-800-469-4663)

8. Check with gas utility company
9. See service and adjustment section for

inspection and cleaning of flame arrestor
& burner

10. Clean pilot

HIGH OPERATION COSTS

1. Thermostat set too high
2. Sediment or lime in tank

3. Water heater too small for job
4. Wrong piping connections

5. Leaking

faucets

6. Gas

leaks

7. Wasted hot water
8. Long runs of exposed piping
9. Hot water piping in exposed wall

1. Set temperature dial to lower setting
2. Drain/flush-provide water treatment if

needed

3. Install adequate heater
4. Correct piping-dip tube must be in cold

inlet

5. Repair

faucets

6. Check with utility-repair at once
7. Advise

customer

8. Insulate

piping

9. Insulate

piping

INSUFFICIENT HOT WATER

1. Thermostat set too low
2. Sediment or lime in tank

3. Water heater too small
4. Wrong piping connections

5. Leaking

faucets

6. Wasted hot water
7. Long runs of exposed piping
8. Hot water piping in outside wall
9. Low gas pressure

1. Turn temperature dial to desired setting
2. Drain/flush-provide water treatment if

needed

3. Install adequate heater
4. Correct piping-dip tube must be in cold

inlet

5 Repair

faucets

6. Advise

customer

7. Insulate

piping

8. Insulate

piping

9. Check with gas utility company

SLOW HOT WATER
RECOVERY

1. Insufficient air

2. Flue

clogged

3. Low gas pressure
4. Improper

calibration

5. Thermostat set too low
6. Water heater too small
7. Wrong piping connections

8. Wasted hot water

1. Provide ventilation to water heater.

Check flue way, flue baffle, and burner

2. Clean flue, locate source and correct
3. Check with gas utility company
4. Replace

thermostat

5. Turn temperature dial to desired setting
6. Install adequate heater
7. Correct piping-dip tube must be in cold

inlet

8. Advise

customer

TROUBLESHOOTING GUIDE