Product features

This appliance has been designed for charging a
variety of SLA batteries (sealed lead acid batteries),
as mainly used in cars, motorbikes and several other
vehicles. They may be of types e.g. WET (with liquid
electrolyte), GEL (with mit gel-type electolyte) or AGM
(absorbed glass mat) batteries. Their capacity ranges
from 12 V / 1.2 Ah to 12 V / 120 Ah.
A special design of the appliance (also named
„three-phase-charging strategy“) enables the recharg-
ing of the batttery to almost 100 % of its original
capacity. Furthermore, a long-term connection of the
battery to the charging station can take place to
keep the battery in optimal condition when not in
use, without it being damaged in the process.

Q



Operation

Q



Preparing for use

m

Caution! Danger of electric shock!
Only install, maintain and service the appliance
when it is disconnected form the mains!

Working safely

j

When putting the appliance into operation,

select a suitable place to do so.

j

Take your time when carefully preparing to put

the appliance into operation. Put all compoments
and any additionally required tools or materials
well arranged and within easy reach.

j

Always be alert and pay attention to what you

are doing. Be sensible when working and do
not operate the charging station if you lack the
ability to concentrate or do not feel well.

Q



Connection

j

Before starting the charging or discharging

procedure on a permanently installed battery
in a vehicle, first disconnect the minus pole con-

necting cable (black) of the vehicle from the
minus pole of the battery. The minus pole of the
battery is usually connected to the car body.

j

Then disconect the plus pole connecting cable

(red) of the vehicle from the plus pole of the
battery.

j

Then first connect the „+“ pole quick-contact

clamp (red)

14

of the charging station to the

plus pole („+“ pole) of the battery.

j

Connect the „–“ pole quick-contact clamp (black)

15

to the „–“ pole of the battery.

j

Connect the power cord

10

of the battery

charging station to the socket oulet with earthing
contact of the power supply.

Q



Disconnecting

j

Disconnect the appliance from the power supply.

j

Disconnect the „–“ pole quick-contact clamp

(black)

15

from the „–“ pole of the battery.

j

Disconnect the „+“ pole quick-contact clamp

(red)

14

from the „+“ pole of the battery.

j

Reconnect the plus pole connecting cable of

the vehicle to the plus pole of the battery.

j

Reconnect the minus pole connecting cable of

the vehicle to the minus pole of the battery.

Q



Select charging mode

For charging various batteries at different ambient
temperatures you can choose between three different
charging modes. Select the most efficient and suita-
ble charging mode for charging the battery.
In comparison with conventional battery charging
stations, this appliance has a special function for
reusing an empty battery or rechargeable battery.
You can recharge an empty battery / rechargeable
battery. Safe charging is ensured by means of a
protection function against incorrect connection and
short circuiting. Due to the installed electronics, the
charging station does not begin operation directly
after connecting the battery, but only starts after a
charging mode has been selected.