Kuma Stoves K-300 User Manual

Page 12

Advertising
background image




Section O-

Figures 1-5

Flame Deflector Plate




*All Top surfaces to be gasketed
With 1/8” gasket before replacing baffle
system

Bypass

Control

Rod

3/8 X 3/4 S.S.
(16 thread)

Bypass Plate
1/2” thickness

15 1/2”

Figure 1

“C”- Catalytic hold
down clamp

22

1 1/2”

3 5/8”

1 1/2”

14”

5/8”

“B”

“A”

1” Clearance
Between Catalytic
and flame
deflector

“D” Catalytic Units (2)

2 1/2” Tall
7 1/2” Wide
3” Deep
16 Cells per sq. Inch

Re-gasket each catalytic unit once with 1/8” X 2” gasket
Wrap each pre-wrapped unit with 1/8” X 2” gasket

Typical Home Installation

All KUMA stoves must be installed and operated in
accordance with all local, state, and Federal laws,
codes, and ordinances.

NOTE: All reduced clearance installations must use
U.L. approved double wall stove pipe.

C

D

B

A

Figure 2

Standard Reduced
Clearance Clearance

Pipe Connector

Floor Protector

8”

Min.

8” Min.

8”

Min.

18” Min.

Stove

E

E

F

G

Stove

Stove

Figure 3

Figure 4

Figure 5

A =14
B =18
C =22
D =36
E =24
F =22
G=36

A =7
B =11
C =15
D = 27
E =19
F =15
G =27

U.S. (in inches)

Canada (en mm)

A =406
B =508
C =635
D =914
E =660
F =432
G=914

A =229
B =330
C =406
D =686
E =533
F =305
G=686