SERVICE MANUAL

32

30APR96 – SM4530-1

Adjusting the NULL

Warning

Dangerous Voltage

[1] Disconnect the main power.

[2] Do the removal for the LOWER HOUSING ASSEMBLY.

Important

• It is necessary to make a FAN COVER TOOL. See the Tools section.

• If you cannot obtain the NULL position after doing the adjustment approximately 3 times, go to the adjustment

procedure for the PHOTOCELL.

[3] Install the FAN COVER TOOL over the FAN area and the LAMP MODULE. See the Tools section.

[4] Energize the projector.

[5] Set the projector to the LO-LAMP position.

[6] Install and hold the AUTO FOCUS TARGET SLIDE TL-3002 until it is fully seated in the GATE MECHANISM.

[7] Look through the PROJECTION LENS hole and observe the focus light path on the AUTO-FOCUS TARGET

SLIDE TL-3002. Check that the light image is correct. If not, do the Adjusting the FOCUS LIGHT PATH.

[8] Check that the TAB on the CLAMP PAD ASSEMBLY is in the NULL position. If the TAB is not in the correct

position, do the adjustment procedure for the NULL.

[9] Bend the PHOTOCELL BRACKET to move the NULL in the center; use T-BAR TL-3003.

Adjustment Specification

Use TL-3002 and FAN CAP 232729 to check the adjustment of the PHOTOCELL.

A091_4031BA

TL-3002

TARGET SLIDE

AUTO-FOCUS

A091_4031BCA

LENS

PROJECTION

light path

NULL position

PAD

CLAMP LEVER

TAB

T-BAR
TL-3003