Koblenz/Thorne Electric FELICIDADES U-900 User Manual

Page 5

Advertising
background image

-5 -

VACUUM ASSEMBLY

1. Remove the handle screw.
2. Insert handle into top of dust cover with handle switch facing forward.
3. Align small hole on handle with screw hole in dust cover.
Insert screw and tighten securely. (All models)
4. Turn cord storage hook to upright position and wind cord between upper and lower hooks to store.
5. To quick-release cord: simply rotate hook downward and cord will drop for immediate use.

*Remember: Always have a dust bag installed when operating your Vacuum Cleaner.
Replace with a genuine dust bag when full.
1. Push down on knob at top of dust cover to open compartment.
2. Pull cardboard bag collar off holder. Remove and discard used dust bag.
3. Slide clean replacement bag collar onto holder.
4. Close dust cover by reinserting tab on lower edge into groove on housing and snap shut.

*Important: The secondary filter protects the motor from dust and dirt.
1.Check for accumulated dust and dirt when replacing dust bag.
2. If replacement is needed, release the right tab on underside of bag supporter.
Lift and rotate bag supporter to remove.
(Bag supporter for Model U-900)
3. Remove secondary filter from bottom of dust compartment.
4. Replace secondary filter with new filter.
5. Reinstall bag supporter.

ATTACHING THE HANDLE

REPLACING THE DUST BAG:

CHECKING THE SECONDARY FILTER:

Advertising
This manual is related to the following products: