Kobe Range Hoods CH7630SQB User Manual

Page 9

Advertising
background image

7

4. Draw electrical wires through cabinet

access opening.

5.

From inside of the hood, place screw (not
provided) into the exact center of each
knockout hole and secure to cabinet bottom.
Once all mounting screws are in place,
finish tightening screws until secure.

CAUTION

: MAKE SURE THE

HOOD IS SECURE BEFORE RELEASING.

6.

For safety purpose, pre-drilled mounting
holes are provided through the back of the
hood. For a more secure installation, use as
many mounting holes as needed to secure
from the inside of hood (screws not
provided).

Ductwork Installation

7. Use 7 round steel pipe (follow building

codes in your area) to connect the exhaust
on the hood to the ductwork above. Use
duct tape to make all joints secure and air
tight. Refer to Figure 4.

Wiring to Powe r S upply

6$)(7< :$51,1*

RISK OF ELECTRICAL SHOCK. THIS
RANGE HOOD MUST BE PROPERLY
GROUNDED. MAKE SURE THIS IS DONE BY
QUALIFIED ELECTRICIAN IN ACCORDANCE
WITH ALL APPLICABLE NATIONAL AND
LOCAL ELECTRICAL CODES. BEFORE
CONNECTING WIRES, SWITCH POWER OFF
AT SERVICE PANEL AND LOCK SERVICE
PANEL TO PREVENT POWER FROM BEING
SWITCHED ON ACCIDENTALLY.
8. Connect the electrical wires.

-

Connect three wires (black, white and
green) to house wires and cap with wire
connectors. Connect according to color:
black to black, white to white, and green
to green as shown in Figure 5.

-

Store wires in the wiring box.

Figure 4

Figure 5

Figure 6

Advertising
This manual is related to the following products: