19.eps, Ab c, Commissioning – Kohler CFI230G User Manual

Page 10

Advertising
background image

Measure the distance of the glass between

the wall jamb and the tray ‘A’. Cut the

splashguard to size cutting at the wall jamb end.

Fit the splashguard to the bottom of the glass

10

19

CFI230G

STEP

19

STEP

20

If the any further adjustment is required to make

the glass panel vertical turn the 4 screws ‘D’

until the panel is in the correct position

D

STEP

18

COMMISSIONING

1. General

1.1.

Turn on the water supply to the Digital Mixer.

1.2.

Check for leaks over the complete system.

1.3.

Turn on the electrical supply to the Digital Mixer.

For the Pumped Version with the Slider Rail Shower System, pump priming can be helped by removing the

handset and lowering the end of the hose into the shower tray.

2. Set the Maximum Temperature

Note!

The maximum temperature of the unit can only be set when the unit has not been used for a period of

10

minutes.

2.1.

Temperature Selection - Set the temperature control knob to the desired position, as per the table

below.

2.2.

Enabling - Press and momentarily hold the Warm Up and High keys at the same time. Release the

push-button and reselect within 2 seconds. The two keys will flash twice and beep three times to

confirm the selection is successful.

3. Lock Mode

Note!

Allows you to lock the unit during operation.

3.1.

Selection - Press and momentarily hold the Warm Up and Medium keys at the same time. The two

keys will flash twice and beep three times to confirm the selection is successful.

3.2.

Operation - This mode locks out all the keys except the Warm Up/Off key. It also locks the temperature

control knob. Once selected it is only possible to turn the unit OFF.

Selecting Warm Up/Off and Medium at the same time again, cancels the lock mode.

Temperature Control

Temperature Selection oC

Knob

Position

1

Factory Set 45

2

39

3

40

4

42

5

43

6

44

7

45

7.5

46

8

47

9

48

STEP

21

A

CFI230G

A

B

C

The edge of the glass should fit against the end

of the slot in the tray ‘B’. To adjust the glass

loosen the 4 screws ‘C’ and move the panel until

it is the correct postion. Re-tighten screws

Check the wall channel and jamb is vertical.

Loosen screws ‘A’ to adjust from side to side.

Re-tighten screws

Check end of

glass is vertical