AlphaServer 8400 Power Configuration Table

3.226 Alpha Servers

AlphaServer 8400 EPU (Equivalent Power Units)



Power Configuration Table



Second power regulator may be needed to supply additional 48V power to the system.



Mixing of three-phase and single-phase power regulators in system configuration is not allowed.



Use chart to determine need for second power regulator.



If EPU is greater than 80, order second power regulator (three-phase regulator

H7263-AC/AD) or H7263-AA/AB if

BBU is required).



EPU must not exceed 180.

Options

EPU Values

System

Cabinet
Options

Quantity

Total

EPU

(Qty times

EPU)

EPU Values

Expansion

Cabinet
Options

Quantity

Total

EPU

(Qty times

EPU)

Base system includes power regulator, CPU module,
system I/O module, memory module

30

1

30

I/O expansion cabinet (H9F00-BA/BB/BC) includes
one power regulator

1

0

Additional 5/300 CPU modules

751P1-AX, 751P2-AX

11

Additional 5/300 CPU modules

752P1-AX, 752P2-AX

13

Additional 5/350 CPU modules

753P1-AX, 753P2-AX

12

Additional 5/350 CPU modules

754P1-AX, 754P2-AX

14

Additional dual 5/440 CPU modules—756P1-AX, 756P2-AX

8

KFTIA-AA System I/O module

4

KFTHA-AA System I/O module

3

MS7CC-BA 128 MB memory

5

MS7CC-CA 256 MB memory

5

MS7CC-DA 512 MB memory

5

MS7CC-EA 1 GB memory

5

MS7CC-FA 2 GB memory

5

MS7CC-GA 4 GB memory

5

Add PCI options

DWLPB-AA/AB/BA/BB

1

KZPSA-BB

1

KZPSC-AA/BA, KZPAC-AA/CA/CB

1

DE435-AA, DE450-AA, DE500-XA, DE500-AA

1

DEFPA-AB/DB/UB/MB

1

KFE70-AA

1

Add EISA options

DNSES-AA

1

DW300-AA

1

CXI01-AA/AD

1

Add XMI options

DWLMA XMI plug-in unit

4

KZMSA-AB XMI SCSI controller

3

KFMSB-AA DSSI disk/tape adapter

3

CIXCD-AC XMI CI controller

4

DEMNA-M XMI Ethernet controller

3

DEMFA-AA XMI FDDI adapter

5

Disk and Tape options

8-bit SCSI disk drives

1

16-bit SCSI disk drives

1

TLZ07, TLZ09, TLZ9L, TLZ15-VA SCSI tape drive

1

TZ86, TZ87, TZ88 -VA SCSI tape drive

3

DWZZA-VA/DWZZB-VW SCSI signal converter

0

Total

Note: Depending on configuration, system offers integral UPS capability that supports all in-cabinet components for at