10-5508 Rev A Service Department (800) 888-7009

8

Next, remove the compression nut that connects the hose to the valve. Replace it with
the original compression nut, attach the hose, and tighten the compression nut finger
tight. Take the ½ inch wrench and rotate the nut ½ to ¾ turn.

Attach the second hose to the plastic elbow by using the needle nose pliers to push the
hose all the way onto the plastic elbow. If you do not properly attach the hose, the
pressure from the compressed air will force the hose off the elbow.

push all the way down on elbow

Take two zip ties and mount the valve by using one tie on each side of the valve to hold
the valve in place. In order for the ties to stay tight, the smooth side of the tie must face
outward.

secure valve with zip ties

Tighten the tie as much as possible, and check to make sure that the valve is securely in
place by testing to see if you can move the valve. Once all the slack is removed from the
zip ties, remove the excess by cutting it with the wire cutters.