Installation, Caution – Lincoln Electric LN IM311-E User Manual

Page 10

Advertising
background image

Other Power Sources: Mount the Adapter Kit to the
side of the power source or some convenient location
so its control cable can be connected to the power
source terminal strip. Use the shock mounted mount-
ing plate as a template to locate the four 5/32" diame-
ter holes that must be drilled in the case side. (Use
caution not to drill into or get chips into any internal
components.) Mount the Adapter Kit with four of the
#10 self-tapping screws provided. Connect the
Adapter control cable to power source terminal strips
per the proper connection diagram.

K350-1 ADAPTER KIT - Turn off power source and all
power to the power source.

Used to connect an LN™-23P (K316L-1) to a Lincoln
power source that has a 14 pin control connector.

Mount the Adapter Kit to the side of the power source
or some convenient location so its control cable can
be connected to the power source terminal strip. See
the mounting instructions form the K350

Connect the Adapter control cable to 14 pin connector
on the power source per the proper connection dia-
gram.

Connect a 12 AWG or larger rubber covered flexible
lead physically suitable for the installation to the volt-
age sensing work lead (#21) coming from the LN23P
control cable connector. For convenience, wrap this
voltage sensing lead around the work lead and tape
in place. Connect it directly to the work or to the work
cable connection

K-276 ENCLOSED 50lb. WIRE REEL SUPPORT
Installation and loading instructions (M-13153) are
supplied with the kit.

---------------------------------------------------------------------------

A-3

INSTALLATION

LN™-23P

A-3

WIRE DRIVE ROLLS AND GUIDE TUBES

The LN™-23P is shipped with the proper drive rolls and
guide tubes factory installed. Do not adjust the idle roll
tension adjusting screw. If the idle roll tension must be
relieved temporarily, see “A” and “B” of Maintenance
Section.

OPTIONAL FEATURES INSTALLATION

INNERSHIELD GUN AND CABLE

Unclip the rubber retaining strap that holds the wire
enclosure cover in place and remove the cover.

Push the wire drive section door latch towards the
rear of LN™-23P and open door.

Loosen the gun locking set screw in the conductor
block on the front of the gear box with a 3/16 hex
Allen wrench.

Lay the cable out straight. Insert the connector on the
conductor cable thru the large grommet in the front of
the wire drive section and into the brass block on the
front of the gear box. Make sure it is all the way in
and tighten the locking set screw with a 3/16 hex
Allen wrench. Keep this connection clean and bright.

Connect the 3 pin gun trigger connector to the lower
receptacle.

If the gun cable being used has a reduced speed
switch, connect the 4 pin reduced speed switch con-
nector to the upper receptacle. If the reduced speed
switch is not used, install the protective cap on the
upper receptacle.

K-350 ADAPTER KIT– Turn off power source and all
power to the power source.

SAM-400 Engine Welders: Attach the shock mounted
mounting plate to the front of the SAM electrical com-
ponent panel to left of the relay case with 4 of the #10
self-tapping screws provided. Older models require
the drilling of 4 5/32 dia. holes into the panel. Connect
the adapter control cable to the SAM terminal strips
per the proper connection diagram.

DC-600 (below code 10500): Attach the triangular
mounting plate to the shock mounted plate of the
Adapter with three of the #10 self-tapping screws pro-
vided. Attach the triangular plate to the side of the
DC-600 adjacent to the control terminal strips using
two roof screws and one front panel screw. Connect
the Adapter control cable to the DC-600 terminal
strips power the proper connection diagram.

CAUTION