Features

1. Diffusing Reflector: White translucent acrylic, 3/16” thick.
2. Inner Dirt Shield: White translucent acrylic, 1/8” thick.
3. Chassis: Steel 20 gauge, semi-gloss white powder-coat finish.
4. Suspension: Swivel (central) stem, 5/8” steel tube. Canopy, steel, 7” Dia.

fastened internally, no exposed hardware. Permits installation on ceilings
with slope of up to 45°. Complies with California Code.

5. Multiple Stems: 3/8” Steel outer pipe stems surround center stem and go

into collector plate.

6. Lampholder: Multi-wattage, 4-pin, will accept either GX24q-3 or

GX24q-4 lamp base.

7. Flange Trim: Steel 20 gauge, Plated or Painted Finish.

Lamping (by others)

Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts.

General Electric

Osram/Sylvania

Philips

26W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp

F26TBX/*/A/4P

CF26DT/E/IN/*

PL-T26W/*/4P

32W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp

F32TBX/*/A/4P

CF32DT/E/IN/*

PL-T32W/*/4P

42W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp

F42QBK/*/A/4P

CF42DT/E/IN/*

PL-T42W/*/4P

*Manufacturers’ color temperature designation.

Electrical

Ballast: Electronic, 2-Lamp HPF, Class P, Programmed Start.
Universal Voltage 120/277V, Multi-Wattage 26/32/42W.

4 Lamps

26 Watt

32Watt

42Watt

Voltage

120V 277V 120V 277V

120V 277V

Total Input Watts

110

110

136

136

186 186

Max. Line Current (amps) 1.11

0.48 1.40

0.60

0.60 0.80

Power Factor

>0.98 >0.98 >0.98 >0.98 >0.99 >0.99

Ballast Factor

1.02 1.02 0.96 0.96

0.95 0.95

THD<10% Minimum Starting Temperature -5°F /-20°C.

Mounting

Mounts directly to 4” outlet box, using crossbar hanger, supplied.

Labels

cULus listed suitable for damp locations.

Application Data

Reflectancies: 80% Ceiling, 50% Walls, 20% Floor.
Light Loss Factor = .75 (.88 BF x .85)
FC (footcandles) at 30” work plane.

ANGLE MEAN CP LUMENS

90

53

95

121

199

100

433

105

834

871

110

1193

115

1470

1453

120

1722

125

1912

1704

130

2053

135

2149

1656

140

2203

145

2215

1386

150

2192

155

2178

1005

160

2136

165

1949

546

170

1666

175

1624

159

180

1756

CERTIFIED TEST REPORT NO. 4A28442A

COMPUTED BY LSI PROGRAM **TEST-LITE**

LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE

CAT. #4A28442APBU, HOUSING COVER WITHOUT FLANGE, 28” DIFFUSER

4-42W PLT TRIPLE TUBE PHILIPS LAMPS. LUMEN RATING = 3200 LMS.

2-ADVANCE BALLAST, #ICF-2S42-M2-LD, 120 VAC

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE

TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

ZONE

LUMENS % LAMP %LUMINAIRE

0-30

311

2.43

3.03

0-40

512

4.01

5.00

0-60

920

7.20

8.97

0-90

1287

10.06

12.54

40-90

774

6.05

7.55

60-90

366

2.86

3.57

90-180

8978

70.15

87.46

0-180

10266

80.21

100.00

** EFFICIENCY = 80.2% **

C

ANDLEPOWER SUMMARY

ANGLE MEAN CP LUMENS

0

395

5

394

38

10

389

15

382

108

20

372

25

360

166

30

342

35

321

201

40

297

45

272

211

50

247

55

221

198

60

193

65

165

165

70

141

75

116

123

80

92

85

71

78

90

53

ROOM

CA

VITY

RA

TIO

COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD
%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

80

70

50

30

10

50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

1

.68 .65 .63 .60 .57 .54 .44 .42 .41 .29 .28 .27 .15 .15 .14 .08

2

.59 .55 .51 .52 .48 .45 .38 .35 .33 .25 .24 .22 .13 .13 .12 .07

3

.52 .47 .42 .46 .41 .37 .33 .30 .28 .22 .21 .19 .12 .11 .10 .06

4

.46 .40 .36 .40 .35 .32 .30 .26 .24 .20 .18 .16 .10 .10 .09 .05

5

.40 .35 .30 .36 .31 .27 .26 .23 .20 .18 .15 .14 .09 .08 .08 .04

6

.36 .30 .26 .32 .27 .23 .24 .20 .17 .16 .14 .12 .08 .07 .07 .04

7

.32 .26 .22 .28 .23 .20 .21 .18 .15 .14 .12 .10 .08 .06 .06 .03

8

.38 .29 .19 .26 .21 .17 .19 .16 .13 .13 .11 .09 .07 .06 .05 .03

9

.36 .26 .17 .23 .18 .15 .17 .14 .11 .12 .09 .08 .06 .05 .04 .02

10

.33 .24 .15 .21 .16 .13 .16 .12 .10 .11 .08 .07 .06 .05 .04 .02

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

ZONAL LUMENS AND PERCENTAGES

28 Inch Diameter
30’ x 30’ x 10’ Space
Luminaire

Spacing: 10’ x 10’

Susp. Dist. 28”

4 Lamps

26W

32W

42W

TTT

TTT

TTT

Illum. (FC)

30

41

54

Maint.
Lum.

8/1

8/1

9/1

Ratio
Watts/

1.10

1.36

1.86

Sq. Ft.

Advertising