Xp/xa432, Xp/xa 2' x 4' lens recessed fluorescent, Ordering information – Lightolier XP432 User Manual

Page 2: Options/accessories, Specifications, Specifications (continued), Photometry, Job information type, Lightolier

Advertising
background image

XP/XA 2' x 4' Lens Recessed Fluorescent

XP/XA432

Page 2 of 2

Static, Flat Steel or Regressed Aluminum Lens Frame, 4 Lamp, T8

Lightolier

a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0303

Section1A/Folio F70-12

Job Information

Type:

Ordering Information

Explanation of Catalog Number. Example: XP2GVA232120SOGLR

Options/Accessories

Special Lens: Substitute VI for .125" nominal pattern. For other lenses, consult
factory.
Access Plates: Top wiring access plate is shipped with fixture as
standard. When access plates are required in advance for wiring
convenience, specify separately. Order Catalog number: ACPX CSP.
Electrical Wiring Options: Consult factory.
Fusing: Internal fast-blow fusing. Suffix: GLR.

Internal slow-blow fusing. Suffix:

GMF.

Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture:
Suffix: R. One per ballast: Suffix: B.
Drywall Kit: Order Catalog Number: FK92x4 (Request Folio OA30-10).

Specifications

Performance: In an installation of 4 lamps 32 W luminaires in a room cavity of
1, with reflectance of 80% ceiling, 50% walls, 20% floor, the C.U. shall not be
less than .87. To control veiling reflections, luminaire output in the 30°-90° zone
shall be not less than 70%.
Materials: Chassis parts are die-formed code gauge cold rolled steel.
Housing is embossed for added strength and rigidity with all edges turned over
for safe handling. Lens frames—(XP) flat full-size steel frame, (XA) regressed
full-size aluminum frame.
Finish: Chassis exterior—white baked polyester enamel. Cavity—white
baked polyester enamel minimum 86% reflectance. Phosphate undercoating.

Specifications (continued)

Lens: Extruded virgin acrylic 3/16" square based female cones,
running 45° to the panel edge. .095" nominal thickness (similar to
pattern 12).
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.

Photometry

Model No. XP2GVA432120O4

25.0
41.0
70.0
83.0

0

0.0

83.0

0

30.0

0

50.0

0

84.0

100.0

00

0.0

100.0

83.0%

XP = Recessed

Fluorescent
with Flat Steel
Lens Frame

XA = Recessed

Fluorescent
with Regressed
Aluminum
Lens Frame

2

Fixture

Width

VA

Lens Shielding

Type:

VA = Virgin Acrylic

(standard) see
options and
consult factory

4

Lamp Quantity:

(By others)

4 = 4-Lamp

32

Lamp Fixture

Length:

32=T8,

4' Length

Voltage:

120 or 277

Options:

Add appropriate

suffix to catalog

no, ie: (GLR)

Ballast:

<20THD <10THD

2-2 Lamp Elec. (T8)

SO*

H

I

*

1-4 Lamp Elec. (T8)

O4*

H4*

LOL Dimming (T8)

PS

*Instant Start Standard
Other dimming options. Consult factory.

coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)

RF

20

20

20

RC

80

50

30

RW

70

50

30

50

30

10

50

30

10

1

91

87

84

82

79

77

78

76

74

2

83

76

71

72

68

64

69

66

63

3

76

68

61

64

59

55

62

57

54

4

70

60

53

57

51

47

55

50

46

5

64

54

47

51

45

41

50

45

40

6

60

49

42

47

41

36

45

40

36

7

55

44

37

42

36

32

41

36

32

8

52

41

34

39

33

29

38

32

28

9

48

37

31

36

30

26

35

30

26

10

45

34

28

33

27

23

32

27

23

visual comfort probability (rated lumens per lamp 2850.)

room size

ceiling height

ceiling height

W

L

8.5

10.0

13.0

16.0

8.5

10.0

13.0

16.0

20

20

54

59

67

76

53

57

63

72

20

30

46

51

57

64

47

50

54

61

20

40

41

45

51

57

43

46

49

53

20

60

37

41

45

51

39

42

45

49

30

20

56

60

65

73

55

59

63

71

30

30

47

51

55

62

48

51

54

59

30

40

42

45

49

54

43

46

49

52

30

60

37

41

43

48

39

42

44

47

30

80

35

38

40

44

37

40

41

44

40

20

58

62

67

72

57

61

65

71

40

30

49

53

56

61

49

53

55

59

40

40

43

46

50

53

45

47

49

52

40

60

38

41

43

47

40

43

44

47

40

80

35

38

39

43

38

40

41

44

40

100

34

36

37

40

37

39

39

42

60

30

50

54

57

62

50

54

56

60

60

40

44

48

50

54

45

48

50

53

60

60

39

42

43

47

41

43

44

47

60

80

35

38

39

43

38

40

41

44

60

100

34

36

37

40

36

38

39

41

100

40

47

50

53

57

48

51

52

55

100

60

42

44

46

49

43

45

46

49

100

80

38

40

41

44

40

42

43

45

100

100

36

37

38

41

38

40

40

41

room cavity ratio

luminaries lengthwise

luminaries crosswise

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.

Ceiling Type:

G = Grid (lay-in)

T-bar

F = Flanged

(overlap)
Z spline and
plaster
frame

LER = FL - 74.3

IW - 112

BF - 0.88

Comparative yearly lighting energy cost per 1000 lumens = $3.23