1

COMPONENT LOCATIONS

WIRING DIAGRAM

222162 B IMAGE 3

RED/GREEN
POWER/ACCESS
INDICATOR

YELLOW
"LOCKOUT"
INDICATOR

KEYPAD

SOLID STATE
WHITE LED
DOWN LIGHT

MASTER CODE
RESET JUMPER
(JP2)

TERMINAL
BLOCK #1
(TB1)

TERMINAL
BLOCK #2
(TB2)

BEEPER
LEVEL
JUMPER (JP1)

FACEPLATE

BEZEL

MOUNTING
PLATE

1 - AC OR DC

2 - AC OR DC

3 - N.O.

4 - COM

5 - N.C.

6 - N.O.

7 - COM

8 - N.C.

SENSE - 8

COM - 7

REQUEST-TO-EXIT - 6

EARTH GROUND - 5

OUTPUT #3 COM - 4

OUTPUT #3 - 3

OUTPUT #4 - 2

OUTPUT #4 COM - 1

12-24 VOLT

AC OR DC

POWER

MAIN RELAY

5 AMPS @

28 VDC MAX.

AUXILIARY

RELAY 1 AMP

@ 28 VDC MAX.

TERMINAL

BLOCK 2

TERMINAL

BLOCK 1

AK-2W TERMINALS

CAUTION

IF THE UNIT IS AC POWERED,

MAKE SURE THE SECONDARY OF THE

SYSTEM TRANSFORMER IS ISOLATED

FROM EARTH GROUND

OPTIONAL WIRING

REQUIRED WIRING

OTHER WIRING

NOTES:
1. ALARM SHUNT SET FOR AUXILIARY RELAY
2. TERMINAL BLOCK #2, TERMINAL 8 SET FOR DOOR SENSE

GROUND

STAKE

N.C. DOOR

SWITCH

ALARM

CONTACT

TO ALARM

SYSTEM

POWER
SUPPLY

ELECTRIC

DOOR

STRIKE

AUXILIARY

OUTPUTS

100 mA MAX.
TO COMMON

REQUEST

TO EXIT

BUTTON

TYPICAL DOOR INSTALLATION WIRING

Figure 1. Component Locations