Controls and settings – Lincoln Electric COBRAMAX IM774 User Manual

Page 12

Advertising
background image

CobraMAX™ Owner's Manual - Page 2

Gas Hose

The gas hose is secured over the barbed gas fitting with a tie wrap. The

cabinet end of the gas hose uses our standard gas fitting (1/8” - 27 nps).

Water Hose

If so equipped, one end of the water hose is secured over the barbed water

fitting with a tie wrap and the other end is connected to the center fitting on

the power block.

Electric Cable

A seven conductor control cable is used on the CobraMAX

gun. The gun

end of the control cable is secured to the gun with a boot clamp and soldered

to the pot assembly, tirgger and water leads. Slack is left in the electric cable

as it exits the back of the gun to prevent cable breakage. The cabinet end

has a seven pin “W” clocked amphenol connector.

Section B

Operation

General

The CobraMAX

gun maintains a constant, steady, uniform wire feed speed,

regardless of curved or looped wire conduit. The constant push exerted

by the slave motor in the cabinet, combined with the pull of the gun motor,

causes the wire to literally float friction-free through the wire conduit. The

24VDC gun motor is controlled by a three and three-quarter (3 3/4) turn

potentiometer in the gun handle.

Controls and Settings

Potentiometer

The laterally-positioned potentiometer is located in the lower end of the

handle, providing up to 800 ipm with 3 3/4 turns.

Micro Switch

The micro switch assembly consists of the micro switch and leads.

Trigger Sensitivity

The amount of trigger level travel can

be shortened for a "quicker" or "more

responsive" action.
A more sensitive trigger lever is

produced by reducing the gap between

the trigger lever and the micro switch

lever. By turning-in the trigger sensitivity

adjustment screw, it closed the gap

between the trigger lever and the micro

switch lever.
This will enable the operator to increase

the sensitivity of the trigger lever.

Sensitivity Adjustment

With the wire feeder turned on (with

or without welding wire loaded), turn

the screw in until the micro-switch is

activated. Once activated, the tortch and

wire feeder motors will begin feeding

wire. Retract the screw accordingly until

the system is deactivated and adjusted to

the operators' liking.

Advertising