VI. RESETTING RAINFALL INFORMATION

A. RAINFALL QUANTITY TOTALS


Resetting the Rainfall Quantity Totals will clear the numeric data held
under “TOTAL,” “1h,” and “24h,” resetting all to 0.00 (appearing in
LCD 5).

From any selected normal display mode:

1. Press and hold the RAIN button for 3 seconds.
2. Resetting will automatically shift to display “TOTAL.” The

numeric data under “TOTAL” in LCD 5 will read 0.00.


Note: Resetting the Rainfall Quantity Totals does not affect the Rainfall
History represented in the bar graph.

B. MANUAL SETTING OF THE RAIN MULTIPLICATOR


Note: The rain multiplicator is the height of rain held in the
teeter-totter bucket (inside the rain gauge) before it is tipped. It is
preset to a value of 0.267mm by the manufacturer prior to shipping;
this number produces the most accurate rainfall measurement. There is
no need to manually set this number unless it has been changed.

1. Remove the batteries and wait 30 seconds. (This will also reset the

Rainfall Quantity Totals).

2. Checking the polarity, install batteries.
3. During the brief 2 seconds that all LCD screens light up,

simultaneously press and hold the MOON and MIN/MAX buttons.

4. Three numbers will appear in LCD1 (“267” is the default), with the

last digit (7) flashing.

5. Use the CH/+ button to change the last digit to a 7 and press the

SET button.

6. Use the CH/+ button to change the middle digit to a 6 and press

the SET button.

7. Use the CH/+ button to change the first digit to a 2 and press the

SET button. The Weather Center will enter into normal operating
mode. Do not press any buttons while the Weather Center searches
for transmisssion signals.

8. Follow Program Mode for set-up proceedures.